Intraocular pressure variation associated with the wear of large corneal rigid gas permeable lenses.

Roopa U, Vadath Mathews G, Nair Visakh G, Chacko Anu, Prabhu Avinash V

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Speciality contact lenses are utilized for both ocular surface disorders and refractive error corrections. Common and widely used among them are large corneal rigid gas permeable lenses such as corneo-scleral and mini-scleral lenses. These lenses are designed to rest on the conjunctival tissue overlying the sclera to create a vault over the entire cornea and limbus. The lenses fit in and settle into conjunctival tissue, compressing the collector channels and episcleral veins, directly affecting the aqueous outflow. Consequently, an increase in intraocular pressure (IOP) is anticipated. This study aims to determine the effect of large corneal lens wear over IOP. This included evaluation of IOP variations, corneal thickness variations, and topographic changes before and after large corneal rigid gas permeable lens wear.

METHODS

An interventional study was performed on 30 subjects who had attended the outpatient department of the institute and undergone ophthalmic and medical examinations along with contact lens fitting tests. IOP, corneal thickness, and corneal curvature measurements were captured before and immediately following 6 h of lens wear.

RESULTS

The average value of intra-ocular pressure before wearing lenses was 11.77 ± 1.77 mmHg and after wearing corneoscleral lenses was 12.17 ± 1.96 mmHg and mini-scleral lens was 12.03 ± 1.92 mmHg. Average values of central corneal thickness (CCT) before wearing lenses were 531.07 ± 20.58 μm and after wearing were 537.33 ± 20.68 μm for corneo-scleral lens and 540.60 ± 20.30 μm for mini-scleral lens.

CONCLUSION

There was substantial increase in intra-ocular pressure and CCT after wearing both corneo-scleral lens and mini-scleral lens for 6 h. There were no significant changes seen in corneal curvature after wearing both lenses.

Для цитирования: Roopa U, Vadath Mathews G, Nair Visakh G, Chacko Anu, Prabhu Avinash V. Intraocular pressure variation associated with the wear of large corneal rigid gas permeable lenses.. Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society. 2024. DOI: 10.4103/sjopt.sjopt_189_24.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.