DOI 10.1186/s40942-025-00774-2

Медицинская библиотека · International journal of retina and vitreous · 2025

Transconjunctival suprachoroidal buckling for rhegmatogenous retinal detachment.

El Rayes Ehab N, Al Tayyar Ahmed, Gotzaridis Stratos, Hsieh Yi-Ting

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To assess the effectiveness of the transconjunctival suprachoroidal buckle (TSCB) technique in treating primary rhegmatogenous retinal detachment (RRD).

METHODS

A prospective interventional study including patients with primary RRD undergoing the TSCB technique. The technique consisted of a transconjunctival approach using an olive tip handled cannula with an Atkinson 25-gauge needle tip that injects a high-purity gel in the suprachoroidal space (SCS) and creates a buckle effect that lasts for 12–18 months. Indirect laser retinopexy is done in the operating room or in the early post-operative office visit on the slit lamp. The TSCB technique could be done in the office in selected cases of uncomplicated RRD.

RESULTS

The study included 31 eyes of 31 patients. Seventeen eyes were phakic (55%). The RRD involved one quadrant in 81% of eyes. Sixteen eyes (52%) had more than one break. The TSCB procedure was performed in the operating room in 21 patients (68%). The mean duration of follow-up was 5 months. Postoperatively, we achieved retinal attachment in all patients. Three patients (10%) needed a second surgery. Two patients (6%) developed dot hemorrhage due to choroidal puncture.

CONCLUSION

The TSCB is safe, and avoids the complications of conventional scleral buckling.

Для цитирования: El Rayes Ehab N, Al Tayyar Ahmed, Gotzaridis Stratos, Hsieh Yi-Ting. Transconjunctival suprachoroidal buckling for rhegmatogenous retinal detachment.. International journal of retina and vitreous. 2025. DOI: 10.1186/s40942-025-00774-2.