MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-023-38845-9

Медицинская библиотека · Scientific reports · 2023

Analysis of widefield choroidal thickness maps of healthy eyes using swept source optical coherence tomography.

Hirano Masatoshi, Muraoka Yuki, Kogo Takahiro, Ishikura Masaharu, Nishigori Naomi, Ueda-Arakawa Naoko, Miyata Manabu, Hata Masayuki, Takahashi Ayako, Miyake Masahiro, Tsujikawa Akitaka

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We aimed to obtain widefield (WF) swept source optical coherence tomography (SS-OCT) data and examine the features of choroidal thickness maps in healthy eyes. The posterior pole choroidal thickness was examined in 127 eyes using enhanced depth imaging of SS-OCT with a viewing angle of 20 (vertical) × 23 (horizontal) mm, and choroidal thickness maps were generated. For SS-OCT image analysis, we developed a grid with inner and outer rings, each divided into superotemporal, inferotemporal, superonasal, and inferonasal quadrants, comprising a total of nine subfields, including the central 3-mm ring. The posterior pole choroidal thicknesses were significantly lower at the periphery than in the central area, in the inferior field than in the superior field, and in the nasal field than in the temporal field (p < 0.001 for all). We also evaluated the effects of age and axial length (AL) on the WF choroidal thickness. The choroidal thickness in all subfields was negatively associated with advanced age (p < 0.05). The choroidal thicknesses in the central and inferonasal inner and outer subfields were negatively associated with AL (p = 0.042, 0.034, and 0.022, respectively). These findings provide insights into the two-dimensional characteristics of choroidal thickness and its association with age and AL.

Для цитирования: Hirano Masatoshi, Muraoka Yuki, Kogo Takahiro, Ishikura Masaharu, Nishigori Naomi, Ueda-Arakawa Naoko, Miyata Manabu, Hata Masayuki, Takahashi Ayako, Miyake Masahiro, Tsujikawa Akitaka. Analysis of widefield choroidal thickness maps of healthy eyes using swept source optical coherence tomography.. Scientific reports. 2023. DOI: 10.1038/s41598-023-38845-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.