BMC ophthalmology · 2023
Vitrectomy with sulfur hexafluoride versus air tamponade for idiopathic macular hole: a retrospective study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yao Yuou, Yan Huichao, Qu Jinfeng, Dong Chongya, Liang Jianhong, Yin Hong, Ren Chi, Jin Enzhong, Zhao Mingwei
Аннотация
BACKGROUND: To evaluate the effect of room air and sulfur hexafluoride (SF6) gas in idiopathic macular hole(MH)surgery.
METHODS: Retrospective, interventional, and comparative study. 238 eyes with the idiopathic macular hole that underwent pars plana vitrectomy, internal limiting membrane peeling, fluid-air exchange, and 20% SF6 (SF6 group:125 eyes) or room air tamponade (air group: 113 eyes) were reviewed. The primary outcome measure was the closure rate of primary surgery.
RESULTS: The baseline characteristics of the SF6 group and air group were comparable except for the hole size (479.90 ± 204.48 vs. 429.38 ± 174.63 μm, P = 0.043). The anatomical closure rate was 92.8% (116 / 125) with the SF6 group and 76.1% (86 / 113) with the air group (P < 0.001). A cut-off value of MH size to predict primary anatomical closure was 520 μm, which is based on the lower limit of 95% confidential interval of the MH size among the unclosed patients in the air group. There was no significant difference in anatomical closure rates between SF6 and air group (98.7% vs. 91.9%, P = 0.051) for MH ≤ 520 μm, whereas a significantly lower anatomical closure rate was shown in the air group than SF6 group (46.2% vs. 84.0%, P < 0.001) for MH > 520 μm.
CONCLUSION: SF6 exhibited more effectiveness than air to achieve a good anatomical outcome for its longer tamponade when MH > 520 μm.
METHODS: Retrospective, interventional, and comparative study. 238 eyes with the idiopathic macular hole that underwent pars plana vitrectomy, internal limiting membrane peeling, fluid-air exchange, and 20% SF6 (SF6 group:125 eyes) or room air tamponade (air group: 113 eyes) were reviewed. The primary outcome measure was the closure rate of primary surgery.
RESULTS: The baseline characteristics of the SF6 group and air group were comparable except for the hole size (479.90 ± 204.48 vs. 429.38 ± 174.63 μm, P = 0.043). The anatomical closure rate was 92.8% (116 / 125) with the SF6 group and 76.1% (86 / 113) with the air group (P < 0.001). A cut-off value of MH size to predict primary anatomical closure was 520 μm, which is based on the lower limit of 95% confidential interval of the MH size among the unclosed patients in the air group. There was no significant difference in anatomical closure rates between SF6 and air group (98.7% vs. 91.9%, P = 0.051) for MH ≤ 520 μm, whereas a significantly lower anatomical closure rate was shown in the air group than SF6 group (46.2% vs. 84.0%, P < 0.001) for MH > 520 μm.
CONCLUSION: SF6 exhibited more effectiveness than air to achieve a good anatomical outcome for its longer tamponade when MH > 520 μm.