m+Medelevator.RU
← Поиск публикаций
Translational vision science & technology · 2023

A Novel Device for Suprachoroidal Drug Delivery to Retina: Evaluation in Nonhuman Primates.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rotenstreich Ygal, Sher Ifat, Lawrence Matthew, Mangelus Miriam, Ingerman Avner, Barak Yoreh

Аннотация

PURPOSE: Evaluation of distribution and tolerance of suprachoroidal injection of indocyanine green (ICG) in nonhuman primates (NHPs) using a novel suprachoroidal (SC) delivery technology.

METHODS: Three live and three euthanized African green monkeys were injected with 150 or 200 µL ICG/eye into the SC space of both eyes, 2.5 mm posterior to the limbus in the inferior quadrant, utilizing a novel SC injector. Eyes were analyzed by imaging of scleral flatmounts. Live animals were observed for 24 hours for general health. Ophthalmic evaluation included slit-lamp biomicroscopy, tonometry, fundus imaging, confocal laser ophthalmoscopy, and spectral-domain optical coherence tomography (SD-OCT) before and at 10 minutes and 1, 3, and 24 hours post-injection.

RESULTS: SC dosing was successfully performed in all eyes. Infrared fundus imaging demonstrated ICG distribution throughout the posterior segment, reaching the macula within 24 hours post-injection. No inflammation, intravitreal penetration, SC blebs, retinal detachment, or hemorrhages were detected. No significant changes were observed in retinal thickness by SD-OCT (P = 0.267, ANOVA). A mild, statistically insignificant elevation in intraocular pressure was observed within 10 minutes post-injection (mean ± standard error: 7.28 ± 5.09 mmHg; P = 0.061) and was spontaneously resolved within the first hour after dosing.

CONCLUSIONS: Suprachoroidal injection of 150 to 200 µL ICG dye was successfully performed and well tolerated in NHP eyes, with rapid distribution into the macular region and throughout the posterior pole.

TRANSLATIONAL RELEVANCE: This novel SC drug delivery system may potentially provide safe and effective delivery of therapeutics to the posterior pole region in humans.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты