DOI 10.1007/s00259-023-06248-7
Preclinical and pilot clinical evaluation of a small-molecule carbonic anhydrase IX targeting PET tracer in clear cell renal cell carcinoma.
Аннотация
PURPOSE: Clear cell renal cell carcinoma (ccRCC) highly expresses carbonic anhydrase IX (CAIX). The purpose of this study was to evaluate 68Ga-NY104, a small-molecule CAIX-targeting PET agent, in tumor models of ccRCC and patients diagnosed with confirmed, or suspicious, ccRCC.
METHODS
The in vivo and ex vivo biodistribution of 68Ga-NY104 was investigated in CAIX-positive OS-RC-2 xenograft-bearing models. The binding of the tracer was further validated using autoradiography for human ccRCC samples. In addition, three patients with confirmed or suspicious ccRCC were studied.
RESULTS
NY104 can be labeled with high radiochemical yield and purity. It quickly cleared through kidney with α-half-life of 0.15 h. Discernible uptake is noted in the heart, lung, liver, stomach, and kidney. The OS-RC-2 xenograft demonstrated intense uptake 5 min after injection and gradually increased until 3 h after injection with ID%/g of 29.29 ± 6.82. Significant binding was detected using autoradiography on sections of human ccRCC tumor. In the three patients studied, 68Ga-NY104 was well-tolerated and no adverse events were reported. Substantial accumulation was observed in both primary and metastatic lesions in patient 1 and 2 with SUVmax of 42.3. Uptake in the stomach, pancreas, intestine, and choroid plexus was noted. The lesion in third patient was correctly diagnosed as non-metastatic for negative 68Ga-NY104 uptake.
CONCLUSION
68Ga-NY104 can efficiently and specifically bind to CAIX. Given the pilot nature of our study, future clinical studies are warranted to evaluate 68Ga-NY104 for detection of CAIX-positive lesions in patients with ccRCC.
TRIAL REGISTRATION: The clinical evaluation part of this study was retrospectively registered at ClinicalTrial.gov (NCT05728515) as NYPILOT on 6 Feb, 2023.