MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics14182051

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2024

Standardization of Dual-Energy CT Iodine Uptake of the Abdomen and Pelvis: Defining Reference Values in a Big Data Cohort.

Yel Ibrahim, Booz Christian, D'Angelo Tommaso, Koch Vitali, Gruenewald Leon D, Eichler Katrin, Gökduman Aynur, Giardino Davide, Gaeta Michele, Mazziotti Silvio, Herrmann Eva, Vogl Thomas J, Mahmoudi Scherwin, Lanzafame Ludovica R M

СтатьяПеревод пока не подготовлен

Аннотация

Background

To establish dual-energy-derived iodine density reference values in abdominopelvic organs in a large cohort of healthy subjects.

Methods

597 patients who underwent portal venous phase dual-energy CT scans of the abdomen were retrospectively enrolled. Iodine distribution maps were reconstructed, and regions of interest measurements were placed in abdominal and pelvic structures to obtain absolute iodine values. Subsequently, normalization of the abdominal aorta was conducted to obtain normalized iodine ratios. The values obtained were subsequently analyzed and differences were investigated in subgroups defined by sex, age and BMI.

Results

Overall mean iodine uptake values and normalized iodine ratios ranged between 0.31 and 6.08 mg/mL and 0.06 and 1.20, respectively. Women exhibited higher absolute iodine concentration across all organs. With increasing age, normalized iodine ratios mostly tend to decrease, being most significant in the uterus, prostate, and kidneys (p < 0.015). BMI was the parameter less responsible for variations in iodine concentrations; normal weighted patients demonstrated higher values of both absolute and normalized iodine.

Conclusions

Iodine concentration values and normalized iodine ratios of abdominal and pelvic organs reveal significant gender-, age-, and BMI-related differences, underscoring the necessity to integrate these variables into clinical practice.

Для цитирования: Yel Ibrahim, Booz Christian, D'Angelo Tommaso, Koch Vitali, Gruenewald Leon D, Eichler Katrin, Gökduman Aynur, Giardino Davide, Gaeta Michele, Mazziotti Silvio, Herrmann Eva, Vogl Thomas J, Mahmoudi Scherwin, Lanzafame Ludovica R M. Standardization of Dual-Energy CT Iodine Uptake of the Abdomen and Pelvis: Defining Reference Values in a Big Data Cohort.. Diagnostics (Basel, Switzerland). 2024. DOI: 10.3390/diagnostics14182051.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.