Scalability of an endoluminal spring for distraction enterogenesis.

Rouch Joshua D, Huynh Nhan, Scott Andrew, Chiang Elvin, Wu Benjamin M, Shekherdimian Shant, Dunn James C Y

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Techniques of distraction enterogenesis have been explored to provide increased intestinal length to treat short bowel syndrome (SBS). Self-expanding, polycaprolactone (PCL) springs have been shown to lengthen bowel in small animal models. Their feasibility in larger animal models is a critical step before clinical use.

METHODS

Juvenile mini-Yucatan pigs underwent jejunal isolation or blind ending Roux-en-y jejunojejunostomy with insertion of either a PCL spring or a sham PCL tube. Extrapolated from our spring characteristics in rodents, proportional increases in spring constant and size were made for porcine intestine.

RESULTS

Jejunal segments with 7mm springs with k between 9 and 15N/m demonstrated significantly increased lengthening in isolated segment and Roux-en-y models. Complications were noted in only two animals, both using high spring constant k>17N/m. Histologically, lengthened segments in the isolated and Roux models demonstrated significantly increased muscularis thickness and crypt depth. Restoration of lengthened, isolated segments back into continuity was technically feasible after 6weeks.

CONCLUSION

Self-expanding, endoluminal PCL springs, which exert up to 0.6N force, safely achieve significant intestinal lengthening in a translatable, large-animal model. These spring characteristics may provide a scalable model for the treatment of SBS in children.

Для цитирования: Rouch Joshua D, Huynh Nhan, Scott Andrew, Chiang Elvin, Wu Benjamin M, Shekherdimian Shant, Dunn James C Y. Scalability of an endoluminal spring for distraction enterogenesis.. Journal of pediatric surgery. 2016. DOI: 10.1016/j.jpedsurg.2016.09.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.