m+Medelevator.RU
← Поиск публикаций
Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2021

Optimization of ultrasonographic ureteral jet detection and normal ureteral jet morphology in dogs.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gremillion Christine, Cohen Eli B, Vaden Shelly, Seiler Gabriela

Аннотация

Ureteral jets are visualized with ultrasound as echogenic streams extending from the ureterovesicular junction into the urinary bladder. In clinical practice, diuretics are sometimes administered to increase visibility of ureteral jets, however this has not been well described in the veterinary literature. The purpose of this prospective, crossover study was to describe the normal morphology of canine ureteral jets, determine an optimal protocol for diuretic administration to increase visibility of ureteral jets, and confirm in vitro the effect that differences in specific gravity and velocity have on visibility. Ultrasound of 10 normal dogs was performed at baseline and following 1 mg/kg furosemide administered intravenously or subcutaneously. Increased numbers of ureteral jets were seen post-furosemide administration compared to baseline, with an overall increased number of ureteral jets identified following intravenous administration when compared to subcutaneous administration. Time to first ureteral jet was significantly shorter with intravenous compared to subcutaneous administration. Urine specific gravity significantly decreased following furosemide administration. For the in vitro study, saline solutions of varying specific gravities were infused into a bath of hypertonic saline with specific gravity of 1.037. There was good visibility in vitro with infusion of solutions of specific gravities of 1.010-1.025. Infusion of saline solution with a specific gravity of 1.030 had reduced visibility, while infusion of saline with equivalent specific gravity (1.037) was not visible with B-mode ultrasonography. Both intravenous and subcutaneous furosemide administration significantly increase ureteral jet detection with ultrasound secondary to differences in specific gravity, confirming results of prior studies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты