Magnetic double-J stent: Evaluation of tolerance and impact on quality of life compared to traditional double-J stent.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Diranzo-Garcia M, Pardo-Duarte P, Álvarez-Barrera A, Juan-Escudero J U, Beltrán-Puig M, Monzó-Cataluña A, Rechi-Sierra K, Sánchez-Ballester F, Garcia-Ibáñez J, López-Alcina E

Аннотация

INTRODUCTION: The placement of a ureteral stent is one of the most widely performed procedures in urology. It can have a negative impact on the patients' quality of life, requiring a cystoscopy for its removal. The objective of this study is to evaluate the symptoms and impact on quality of life derived from the use of a magnetic double-J stent (Black Star®) and compare them to those presented in patients with a traditional double-J stent (OptiMed®).

MATERIAL AND METHODS: We conducted a comparative, prospective, randomized study in 46 patients who underwent ureterorenoscopy with double-J stent placement between August 2019 and June 2020. Of all patients included, 23 had a traditional double-J stent placed (group A) and 23 had a magnetic double-J stent (group B) placed. We evaluated the results of the Ureteral Stent Symptom Questionnaire (USSQ) in both groups, assessed the technical difficulty related to stent removal and the pain during the procedure using the Visual Analogue Scale (VAS). We also reviewed the need for medical attention due to problems related to the stent or after its removal.

RESULTS: There were no statistically significant differences between groups regarding the answers in the USSQ and the complications related to the use of the stent. Group B showed less pain (1.52 vs. 4, VAS, p = 0.001) and less difficulty during removal (1.61 vs. 3, p < 0.001) associated with a shorter procedure duration (11.65 min vs. 22.17 min p < 0.001).

CONCLUSIONS: The tolerance shown by the use of magnetic double-J is comparable to the tolerance of traditional stent, since it does not cause an increase in urinary symptoms nor worsens the quality of life of patients during its use.