Processing human urine and ureteral stents for 16S rRNA amplicon sequencing.

Al Kait F, Burton Jeremy P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Ureteral stents are commonly used medical devices that harbor a unique and patient-specific microbial community. This protocol describes an optimized procedure for high-quality DNA extraction from both urine and ureteral stent samples for the purpose of downstream microbiota characterization by amplicon sequencing. Detailed instruction is provided for 16S rRNA gene V4 region sequencing with the Illumina platform, which enables accurate and reproducible microbiota profiling of low bacterial abundance urine and stent samples. For complete details on the use and execution of this protocol, please refer to Al et al. (2020).