Failure of ureteral access sheath insertion in virgin ureters: A retrospective tertiary care center study.
Аннотация
OBJECTIVE
The objective of the study was to identify the failure rate of insertion of ureteral access sheath (UAS) during primary flexible ureteroscopy (FURS).
MATERIALS AND
METHODS
This was a single-surgeon, single-tertiary care center retrospective study. All patients who underwent primary FURS for proximal ureteric or renal stones from November 2014 to May 2018 were included in the study. Patients with a stone burden of more than 20 mm were excluded from the study. A 10/12-Fr coaxial UAS (Bi-Flex, Rocamed) was used. Data collection included age, sex, body mass index (BMI), stone burden and location, previous spontaneous passage of stones, type of anesthesia, and preexisting congenital anomalies. The Chi-square test and t-test were used for the statistical analyses.
RESULTS
One hundred and twelve patients were included in the study. All patients underwent primary FURS. The failure rate of primary UAS insertion was 10.7% (n = 12). No statistically significant difference was found in age, BMI, type of anesthesia, previous history of spontaneous stone passage, and stone burden between the success and failure groups (P > 0.05).
CONCLUSIONS
We believe that our study opens the door for a multicentric prospective trial. Identifying factors leading to a failed primary FURS and UAS insertion is crucial to properly counsel patients preoperatively about the number of procedures that they might need and to prevent the financial loss associated with failed UAS insertion.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.