MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0042-102879

Медицинская библиотека · Endoscopy international open · 2016

A self-assembling matrix-forming gel can be easily and safely applied to prevent delayed bleeding after endoscopic resections.

Pioche Mathieu, Camus Marine, Rivory Jérôme, Leblanc Sarah, Lienhart Isabelle, Barret Maximilien, Chaussade Stanislas, Saurin Jean-Christophe, Prat Frederic, Ponchon Thierry

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Endoscopic resections have low morbidity and mortality. Delayed bleeding has been reported in approximately 1 - 15 % of cases, increasing with antiplatelet/anticoagulant therapy or portal hypertension. A self-assembling peptide (SAP) forming a gel could protect the mucosal defect during early healing. This retrospective trial aimed to assess the safety and efficacy of SAP in preventing delayed bleeding after endoscopic resections.

METHODS

Consecutive patients with endoscopic resections were enrolled in two tertiary referral centers. Patients with a high risk of bleeding (antiplatelet agents, anticoagulation drugs with heparin bridge therapy, and cirrhosis with portal hypertension) were also included. The SAP gel was applied immediately after resection to cover the whole ulcer bed.

RESULTS

In total, 56 patients were included with 65 lesions (esophagus [n = 8], stomach [n = 22], duodenum [n = 10], ampullary [n = 3], colon [n = 7], and rectum [n = 15]) in two centers. Among those 65 lesions, 29 were resected in high risk situations (9 uninterrupted aspirin therapy, 6 heparin bridge therapies, 5 cirrhosis and portal hypertension, 1 both cirrhosis and heparin bridge, 3 both cirrhosis and uninterrupted aspirin, 3 large duodenal lesions > 2 cm, and 2 early introduction of clopidogrel at day 1). The resection technique was endoscopic submucosal dissection (ESD) in 40 cases, en bloc endoscopic mucosal resection (EMR) in 16, piecemeal EMR in 6, and ampullectomy in 3. The mean lesion size was 37.9 mm (SD: 2.2 mm) with a mean area of 6.3 cm(2) (SD: 3.5 cm(2)). No difficulty was noted during application. Four delayed overt bleedings occurred (6.2 %) (3 hematochezia, 1 hematemesis) requiring endoscopic hemostasis. The mean hemoglobin drop off was 0.6 g/dL (- 0.6 to 3.1 g/dL). No adverse events occurred.

CONCLUSION

The use of this novel extracellular matrix scaffold may help to reduce post-endoscopic resection bleedings including in high risk situations. Its use is easy and safe but further comparative studies are warranted to completely evaluate its effectiveness.

Для цитирования: Pioche Mathieu, Camus Marine, Rivory Jérôme, Leblanc Sarah, Lienhart Isabelle, Barret Maximilien, Chaussade Stanislas, Saurin Jean-Christophe, Prat Frederic, Ponchon Thierry. A self-assembling matrix-forming gel can be easily and safely applied to prevent delayed bleeding after endoscopic resections.. Endoscopy international open. 2016. DOI: 10.1055/s-0042-102879.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.