MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0315466

Медицинская библиотека · PloS one · 2025

Impact of digital breast tomosynthesis on screening performance and interval cancer rates compared to digital mammography: A meta-analysis.

Liu Xuewen, Yang Ting, Yao Juan

СтатьяМетаанализСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The performance of digital breast tomosynthesis (DBT) alone, digital mammography (DM) plus DBT, and synthesized mammography (SM) plus DBT, in comparison to DM in breast cancer screening, remains a topic of ongoing debate. The effectiveness of these modalities in reducing interval cancer rates (ICR) is particularly contentious.

MATERIALS AND

METHODS

A database of data was searched for articles published until July 2024. Initially, the pooled sensitivity and specificity of DBT (DBT alone, DM/DBT, and SM/DBT) and DM were estimated. Additionally, the sensitivity of breast cancer screening and ICR for DBT alone, DM/DBT, and SM/DBT compared to DM. The characteristics of interval breast cancer were compared with those screening BC, alongside differences across various screening methods.

RESULTS

Eleven studies comparing DBT and DM were included. The sensitivity of DBT was higher than that of DM, with rates of 86% (95%CI: 81, 90) and 80% (95%CI: 76, 84), respectively. The specificities of both modalities were similar, recorded at 96% (95%CI: 95, 98) and 96% (95%CI: 95, 97), respectively. In comparison to DM, the screening sensitivities of DBT, DM/DBT, and SM/DBT were increased by 4.33% (95% CI: 1.52, 7.13), 6.29% (95% CI: 2.55, 10.03), and 5.22% (95% CI: 1.35, 9.10), respectively; however, the difference in the ICR was not statistically significant.

CONCLUSION

DBT offers advantages in enhancing the sensitivity of breast cancer screening; however, its impact on ICR remains uncertain. Consequently, further research is necessary to comprehensively evaluate both the effectiveness of screening and the potential risks associated with DBT.

Для цитирования: Liu Xuewen, Yang Ting, Yao Juan. Impact of digital breast tomosynthesis on screening performance and interval cancer rates compared to digital mammography: A meta-analysis.. PloS one. 2025. DOI: 10.1371/journal.pone.0315466.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.