BACKGROUND

We performed 163 laparoscopic cholecystectomies at our institution during the third quarter of 2016. Direct supply cost per case varied from $524 to $1,022 among 14 surgeons. The purpose of this study was to determine the reasons for cost variation between high- and low-cost surgeons and identify opportunities for cost reduction.

METHODS

Average cost of supplies per case was examined for laparoscopic cholecystectomy during a 6-month period. Two groups were created, with the 4 highest-cost surgeons comprising group A and the 2 lowest-cost surgeons comprising group B. The cost for each item was identified, and utilization was compared between groups.

RESULTS

The average supply cost per case in group A was significantly greater than group B ($930 vs. $518). The difference persisted in subgroup analyses of both inpatients and patients with high American Society of Anesthesiologists scores. Compared with group A, surgeons in group B used reusable instruments more often and tended to choose lower-cost disposables.

CONCLUSIONS

Significant variation in direct cost exists between surgeons performing laparoscopic cholecystectomy. Much of the cost difference can be accounted for by a relatively small number of high-cost instruments. We identified areas for cost savings by substituting lesser cost alternatives without compromising the quality of patient care.

Для цитирования: Grimes Kevin L, Scott Charleen, McHenry Christopher R. Cost variation and opportunities for cost reduction for laparoscopic cholecystectomy.. Surgery. 2017. DOI: 10.1016/j.surg.2017.10.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.