MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajodo.2006.09.057

Медицинская библиотека · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2008

Sequential bone healing of immediately loaded mini-implants.

Serra Glaucio, Morais Liliane S, Elias Carlos Nelson, Meyers Marc A, Andrade Leonardo, Muller Carlos, Muller Marcelo

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

The relatively small size and the ability to load mini-implants without delay are important changes in the simplification of bone rigid anchorage. The purpose of this study was to analyze interfacial healing 1, 4, and 12 weeks after the placment of titanium mini-implants in New Zealand rabbits by removal torque test (RTT) and scanning electron microscopy (SEM).

METHODS

Eighteen animals were used in the experiment, in which 72 titanium grade 5 mini-implants 2.0 mm in diameter and 6.0 mm long, were placed. Each animal received 4 mini-implants; 2 were immediately loaded with 1 N.

RESULTS

The RTT means for the unloaded mini-implants at 1, 4, and 12 weeks were 15.2 +/- 4.2 N mm (n = 5), 13.1 +/- 5.7 N mm (n = 5), and 54.4 +/- 12.8 N mm (n = 4), respectively. The loaded groups had means of 12.7 +/- 5.1 N mm (n = 4), 11.1 +/- 5.4 N mm (n = 4), and 32.9 +/- 12.8 N mm (n = 5) for the same healing periods, respectively. The statistical evaluation indicated significance in the comparison between loaded and unloaded 12-week groups (P <0.05). SEM analysis in the loaded group showed the formation of less fibrous interfacial tissue after 4 weeks and more lamellar appearance after 12 weeks.

CONCLUSIONS

The immediate 1-N load did not cause significant changes in the fixation of the mini-implants after 1 and 4 weeks of bone healing. Nevertheless, after 12 weeks, the loaded group had significantly lower RTT values than the unloaded group without compromising the stability of the mini-implants (P <0.05).

Для цитирования: Serra Glaucio, Morais Liliane S, Elias Carlos Nelson, Meyers Marc A, Andrade Leonardo, Muller Carlos, Muller Marcelo. Sequential bone healing of immediately loaded mini-implants.. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2008. DOI: 10.1016/j.ajodo.2006.09.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.