MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2006.12.018

Медицинская библиотека · Ophthalmology · 2007

Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy.

Oh Jaeryung, Shin Hyung-Ho, Kim Jun-Heon, Kim Hyo-Myung, Song Jong-Suk

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To measure the ciliary sulcus diameters in 4 different axes and to determine the correlation with white-to-white distance.

DESIGN

Cross-sectional observational study.

PARTICIPANTS

Fourteen normal volunteers with no evidence of ocular disease.

METHODS

Twenty-eight eyes were scanned using a 35-megahertz (MHz) ultrasound biomicroscopy (UBM) in sequential meridional scan planes at 45 degrees increments. Horizontal white-to-white distance was measured using Orbscan IIz (Bausch & Lomb-Orbtek, Inc., Salt Lake City, UT).

MAIN OUTCOME MEASURES: Ciliary sulcus diameter, anterior chamber diameter, white-to-white distance, and coefficient of variation.

RESULTS

The coefficient of variation for 35-MHz UBM was 0.90%. The mean diameters+/-standard deviations of ciliary sulci were 11.55+/-0.38 mm at 45 degrees, 11.99+/-0.36 mm at 90 degrees, 11.54+/-0.36 mm at 135 degrees, and 11.32+/-0.40 mm at 180 degrees. In all eyes, vertical diameters were greater than horizontal diameters. The mean difference between vertical and horizontal diameters was 0.67+/-0.26 mm (range, 0.36-1.13 mm), and this was statistically significant (P<0.001). Horizontal sulcus diameters and horizontal white-to-white distances were not correlated (r = 0.006; P = 0.976).

CONCLUSIONS

The posterior chamber appears to have a vertically oval shape. The white-to-white technique is inaccurate at predicting the horizontal diameter of the ciliary sulcus. The 35-MHz UBM may provide a good means of measuring the ciliary sulcus diameter for the implantation of a posterior chamber phakic intraocular lens.

Для цитирования: Oh Jaeryung, Shin Hyung-Ho, Kim Jun-Heon, Kim Hyo-Myung, Song Jong-Suk. Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy.. Ophthalmology. 2007. DOI: 10.1016/j.ophtha.2006.12.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.