MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.05-0372

Медицинская библиотека · Investigative ophthalmology & visual science · 2006

Demonstration of an anterior diffusional pathway for solutes in the normal human eye with high spatial resolution contrast-enhanced dynamic MR imaging.

Bert Robert J, Caruthers Shelton D, Jara Hernan, Krejza Jaroslaw, Melhem Elias R, Kolodny Nancy H, Patz Samuel, Freddo Thomas F

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The present studies were conducted to determine whether a diffusional pathway for solutes exists from the ciliary body stroma to the anterior chamber of the human eye. The existence of such a pathway has been demonstrated in rabbits and monkeys, but such a pathway in humans would necessitate a shift in the physiological paradigm of the blood-aqueous barrier.

METHODS

Seven normal human volunteers (five men, two women; age range, 27 to 59 years) underwent nine dynamic T1-weighted, spin-echo MR imaging studies, using intravenous, gadolinium-based contrast agents.

RESULTS

In all cases, signal intensity rose rapidly in the ciliary body. In all subjects, there was a measurable latent rise in signal strength (enhancement) in the anterior chamber. Signal enhancement typically occurred in the angle of the anterior chamber earlier, and to a greater degree, than within the center of the chamber. Increased signal within the posterior chamber was significantly less than in the anterior chamber, with measured increases probably attributable to volume averaging.

CONCLUSIONS

These findings are consistent with the existence of an anterior diffusional pathway in the human eye. The model warrants further testing.

Для цитирования: Bert Robert J, Caruthers Shelton D, Jara Hernan, Krejza Jaroslaw, Melhem Elias R, Kolodny Nancy H, Patz Samuel, Freddo Thomas F. Demonstration of an anterior diffusional pathway for solutes in the normal human eye with high spatial resolution contrast-enhanced dynamic MR imaging.. Investigative ophthalmology & visual science. 2006. DOI: 10.1167/iovs.05-0372.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.