Effect of a novel interocclusal recording method on occlusal accuracy of implant-supported fixed prostheses: A randomized clinical trial.

Ding Qian, Pu Tingting, Tu Ya, He Mingzhu, Wang Shimin, Zhang Lei, Liu Jianzhang, Zhou Yongsheng

Рандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To investigate the effect of a novel interocclusal recording method on the occlusal accuracy of implant-supported fixed prostheses for partially dentate patients with distal extension.

MATERIALS AND

METHODS

Twenty patients with two or more adjacent teeth missing in the distal extension and scheduled to receive implant-supported fixed prostheses were enrolled. Two interocclusal recording methods were used: placing polyvinyl siloxane (PVS) on the interocclusal recording caps (test), and placing PVS on healing abutments (control). The intraoral occlusal contacts in maximal intercuspal position (MIP) were compared with those in the mounted casts to calculate sensitivity and positive predictive value (PPV). Then, patients were randomly allocated into two groups to determine which interocclusal record would be used. The implant prostheses' evaluations mainly included occlusal adjustment height, volume, and time, occlusal contact score based on articulating paper examination. Paired-samples t-test, Mann-Whitney U test, and least squares regression analyzed the statistic differences.

RESULTS

The test method had higher sensitivity to detect intraoral occlusal contacts than the control method (p = .002), but similar PPV (p = .10). During the prostheses' evaluations, the occlusal adjustment height in the test group was significantly lower than that in the control group [99.4 (53.2, 134.2) vs. 159.0 (82.3, 247.8) μm, p = .03], while the occlusal contact score before adjustment was higher (p = .006). The groups had similar occlusal adjustment volume and time.

CONCLUSIONS

The novel interocclusal recording method for implant-supported fixed prostheses was more accurate and could reduce the occlusal adjustment.

Для цитирования: Ding Qian, Pu Tingting, Tu Ya, He Mingzhu, Wang Shimin, Zhang Lei, Liu Jianzhang, Zhou Yongsheng. Effect of a novel interocclusal recording method on occlusal accuracy of implant-supported fixed prostheses: A randomized clinical trial.. Clinical oral implants research. 2023. DOI: 10.1111/clr.14040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.