Viscoelasticity-based staging of hepatic fibrosis with multifrequency MR elastography.

Asbach Patrick, Klatt Dieter, Schlosser Beate, Biermer Michael, Muche Marion, Rieger Anja, Loddenkemper Christoph, Somasundaram Rajan, Berg Thomas, Hamm Bernd, Braun Juergen, Sack Ingolf

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the dynamics of the shear modulus of the liver to assess the optimal driving frequency and to determine the diagnostic accuracy of generalized frequency-independent elasticity cutoff values for staging hepatic fibrosis.

MATERIALS AND

METHODS

This institutional review board-approved prospective study included 16 healthy volunteers and 72 patients with biopsy-proved liver fibrosis. After obtaining written informed consent, imaging was performed at 1.5-T by using a motion-sensitized echo-planar imaging sequence. Wave excitation was performed by an actuator introducing a superposition of four frequencies (25.0, 37.5, 50.0, 62.5 Hz) of shear waves. The elasticity µ value and the structure geometry parameter α were calculated by using the two-parameter springpot model. The performance of magnetic resonance (MR) elastography in staging liver fibrosis was assessed with area under the receiver operating characteristic curve (AUROC) analysis and Spearman correlation analysis.

RESULTS

Elasticity increased with stage of fibrosis, with mean values as follows: for volunteers, 2.25 kPa ± 0.43 (standard deviation); stage F1, 2.61 kPa ± 0.43; stage F2, 3.00 kPa ± 0.63; stage F3, 3.86 kPa ± 0.61; and stage F4, 5.86 kPa ± 1.22. Frequency-independent cutoff values derived for fibrosis and AUROC values, respectively, were as follows: stage F1 or higher, 2.84 kPa and 0.9128; stage F2 or higher, 3.18 kPa and 0.9244; stage F3 or higher, 3.32 kPa and 0.9744; and equivalent to stage F4, 4.21 kPa and 0.9931. The geometry of the tissue (α value) did not correlate with fibrosis. Frequencies of 50.0 Hz and 62.5 Hz displayed the highest diagnostic accuracy.

CONCLUSION

The diagnostic performance of multifrequency MR elastography in determining the degree of hepatic fibrosis increases with stage of fibrosis. Metrics obtained at the higher frequencies provide better diagnostic performance compared with the lower frequencies. Results of the AUROC analysis demonstrate the high accuracy of frequency-independent cutoff values for staging higher grades of hepatic fibrosis.

Для цитирования: Asbach Patrick, Klatt Dieter, Schlosser Beate, Biermer Michael, Muche Marion, Rieger Anja, Loddenkemper Christoph, Somasundaram Rajan, Berg Thomas, Hamm Bernd, Braun Juergen, Sack Ingolf. Viscoelasticity-based staging of hepatic fibrosis with multifrequency MR elastography.. Radiology. 2010. DOI: 10.1148/radiol.10092489.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.