DOI 10.1016/j.athoracsur.2026.01.049

Медицинская библиотека · The Annals of thoracic surgery · 2026

Mortality and Reintervention After Robotic Mitral Repair in the United States.

Tam Derrick Y, Razavi Allen A, Sallam Aminah, Chen Qiudong, Emerson Dominic, Bowdish Michael E, Trento Alfredo, Chikwe Joanna

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High-volume centers report acceptable outcomes for robotic mitral repair, yet population-level data are limited. This study compared late mortality and reintervention rates for robotic vs nonrobotic mitral repair in the United States.

METHODS

The Centers for Medicare & Medicaid Services database validated against clinical records was used to identify 26,524 patients with isolated first-time nonemergency mitral repairs with or without tricuspid repairs or ablations without other concomitant procedures. Of these patients, 2227 (8.3%) underwent robotic repair and 24,297 (91.7%) underwent nonrobotic repairs. Propensity score matching was performed on 30 baseline characteristics. The primary end point was a composite of death or mitral reintervention, and the secondary end point was all-cause mortality. Both were compared in a Cox proportional hazards model. Falsification end point analysis assessed for potential unmeasured confounders with death as a competing risk.

RESULTS

Matching yielded 2226 patient pairs (mean age, 72 years; 44% female; 9% with concomitant tricuspid repair; 7% ablation). Thirty-day mortality did not differ between the groups (1.3% robotic vs 1.3% nonrobotic; P = .90). Robotic repair was associated with lower postoperative atrial fibrillation (19.1% vs 23.2%; P = .001) and a shorter hospital stay (median 5 days [interquartile range, 4-7 days] vs 7 days [interquartile range, 5-9 days]; P < .001). At 5 years, the composite of death or mitral reintervention (17.8% vs 18.6%; hazard ratio, 0.93; 95% CI, 0.79-1.09; P = .37) and all-cause mortality (14.9% vs 15.6%; hazard ratio, 0.93; 95% CI, 0.77-1.11; P = .40) were similar, with falsification testing confirming minimal confounding (P = .20).

CONCLUSIONS

Robotic mitral repair in the United States is safe, yielding outcomes comparable to those of nonrobotic repair.

Для цитирования: Tam Derrick Y, Razavi Allen A, Sallam Aminah, Chen Qiudong, Emerson Dominic, Bowdish Michael E, Trento Alfredo, Chikwe Joanna. Mortality and Reintervention After Robotic Mitral Repair in the United States.. The Annals of thoracic surgery. 2026. DOI: 10.1016/j.athoracsur.2026.01.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.