MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-016-0511-6

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016

Early prosthetic aortic valve infection identified with the use of positron emission tomography in a patient with lead endocarditis.

Amraoui Sana, Tlili Ghoufrane, Sohal Manav, Bordenave Laurence, Bordachar Pierre

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

18-Fluorodeoxyglucose positron emission tomography/computerized tomography (FDG PET/CT) scanning has recently been proposed as a diagnostic tool for lead endocarditis (LE).

OBJECTIVE

FDG PET/CT might be also useful to localize associated septic emboli in patients with LE.

CASE PRESENTATION: We report an interesting case of a LE patient with a prosthetic aortic valve in whom a trans-esophageal echocardiogram did not show associated aortic endocarditis. FDG PET/CT revealed prosthetic aortic valve infection. A second TEE performed 2 weeks after identified aortic vegetation. A longer duration of antimicrobial therapy with serial follow-up echocardiography was initiated. There was also increased uptake in the sigmoid colon, corresponding to focal polyps resected during a colonoscopy.

CONCLUSION

FDG PET/CT scanning seems to be highly sensitive for prosthetic aortic valve endocarditis diagnosis. This promising diagnostic tool may be beneficial in LE patients, by identifying septic emboli and potential sites of pathogen entry.

Для цитирования: Amraoui Sana, Tlili Ghoufrane, Sohal Manav, Bordenave Laurence, Bordachar Pierre. Early prosthetic aortic valve infection identified with the use of positron emission tomography in a patient with lead endocarditis.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2016. DOI: 10.1007/s12350-016-0511-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.