m+Medelevator.RU
← Поиск публикаций
Journal of clinical microbiology · 2025

An extraction-free, lyophilized one-pot RAA-CRISPR assay for point-of-care testing of Haemophilus influenzae.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cao Yaling, Wang Junwen, Fan Zihao, Xu Ling, Pan Zhenzhen, Mo Yinkang, Yang Qiwen, Huang Jing, Ren Feng

Аннотация

Timely and accurate diagnosis is essential for the effective treatment of Haemophilus influenzae (HI) infection. Notably, a rapid point-of-care testing (POCT) method for the diagnosis of HI DNA is still lacking. The aim of this study was to establish a one-pot detection device for HI DNA detection using CRISPR/Cas13a that would be applicable for POCT. We established a two-step polymerase chain reaction (PCR)-CRISPR assay, a two-step recombinase-aided amplification (RAA)-CRISPR assay, and a one-pot RAA-CRISPR assay. Additionally, reagent lyophilization, rapid lysis technology, and a one-pot detection device were integrated to construct an extraction-free one-pot detection device, named EFORCA (extraction-free one-pot RAA-CRISPR/Cas13a assay). Validation was performed on 90 simulated samples and 77 clinical samples. The two-step PCR/RAA-CRISPR assay for HI DNA detection was established and optimized, with a detection limit of 1 copy/μL and 100% specificity. The sensitivity and specificity of the two-step PCR-CRISPR assay for the 90 simulated clinical samples were 96.7% and 95%, respectively, and for the 77 clinical samples, 97.5% and 100%, respectively. The one-pot RAA-CRISPR assay and the EFORCA detected 50 and 25 CFU/mL HI in bacterial suspensions within 30 min, respectively. The valuation results for 77 clinical samples demonstrated that the sensitivity of both methods was 95%, which was greater than the sensitivity of quantitative real-time PCR (qPCR) (92.5%) with the same specificity of 100%. We developed an extraction-free one-pot RAA-CRISPR/Cas13a assay for HI detection, which effectively performs a POCT test and is a valuable tool for the early detection and monitoring of HI infection.IMPORTANCETimely and accurate diagnosis is essential for the effective treatment of Haemophilus influenzae (HI) infection. Notably, a rapid point-of-care testing (POCT) method for the diagnosis of HI DNA is still lacking. In this study, sensitive two-step polymerase chain reaction (PCR)-CRISPR and recombinase-aided amplification (RAA)-CRISPR assays were developed, followed by the establishment of the one-pot RAA-CRISPR assay through integration of RAA, CRISPR, and rapid lysis for HI detection. Additionally, reagent lyophilization, rapid lysis technology, and a one-pot detection device were integrated to construct the extraction-free one-pot RAA-CRISPR/Cas13a assay (EFORCA). With its high sensitivity, specificity, rapid turnaround time, and operational simplicity, this assay shows great potential as a practical diagnostic tool for HI infection in small laboratory settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты