MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00276-021-02859-7

Медицинская библиотека · Surgical and radiologic anatomy : SRA · 2021

Analysis of tympanic sinus shape for purposes of intraoperative hearing monitoring: a microCT study.

Bilińska Małgorzata, Wojciechowski Tomasz, Sokołowski Jacek, Niemczyk Kazimierz

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Sinus tympani is the space in the retrotympanum, with variable morphology. Computed tomography is a common tool to investigate sinus tympani anatomy. During cochlear implantation or tympanoplasty, electrocochleography can be used for hearing monitoring. In such a surgical strategy the electrode is placed in the round window's region throughout posterior tympanotomy. Common accessible needle-shaped electrodes using is difficult in achieving intraoperative stabilization. The aim of the study is to assess the dimensions and shape of sinus tympani, basing on the micro computed tomography scans for purposes of establishing the possible new electrocochleography electrode shape.

MATERIALS AND

METHODS

Sixteen fresh frozen cadaveric temporal bones were dissected. MicroCT measurements included the depth and the width of sinus tympani, width of facial canal with stapedius muscle chamber. Obtained data were analyzed statistically with the use of RStudio 1.3.959 software.

RESULTS

The highest average width of sinus tympani amounted for 2.68 mm, depth measured at the round window plane for 3.19 mm. Width of facial canal with stapedius muscle chamber highest average values at the round window plane- 3.32 mm. The lowest average minimum and maximum values were calculated at the 1 mm above the round window plane. The highest average posterior tympanotomy width was 2.91 mm.

CONCLUSIONS

The shape of the tympanic sinus is like a trough with the narrowest and deepest dimensions in the middle part. The ST shape and dimensions should be taken into account in constructing the ECochG electrode, designed for optimal placement through posterior tympanotomy approach.

Для цитирования: Bilińska Małgorzata, Wojciechowski Tomasz, Sokołowski Jacek, Niemczyk Kazimierz. Analysis of tympanic sinus shape for purposes of intraoperative hearing monitoring: a microCT study.. Surgical and radiologic anatomy : SRA. 2021. DOI: 10.1007/s00276-021-02859-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.