Handheld laser-fiber vibrometry probe for assessing auditory ossicles displacement.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Masalski Marcin, Wąż Adam, Błauciak Przemysław, Zatonski Tomasz, Morawski Krzysztof

Аннотация

SIGNIFICANCE: Measurements of auditory ossicles displacement are commonly carried out by means of laser-Doppler vibrometry (LDV), which is considered to be a gold standard. The limitation of the LDV method, especially for in vivo measurements, is the necessity to expose an object in a straight line to a laser beam operating from a distance. An alternative to this approach is the use of a handheld laser-fiber vibrometry probe (HLFVP) with a curved tip.

AIM: We evaluate the feasibility of an HLFVP with a curved tip for measuring sound-induced displacement of the auditory ossicles.

APPROACH: A handheld vibrometer probe guiding the laser beam with a fiber-optic cable was used for displacement measurements of the incus body and the posterior crus of the stapes. Tonal stimuli at frequencies of 0.5, 1, 2, and 4 kHz were presented by means of an insert earphone positioned in the outer ear canal. The probe was fixed at the measurement site using a tripod or hand-held by one of the two surgeons.

RESULTS: The measurements were carried out on six fresh temporal bones. Multivariate analysis of variance showed statistically significant differences for stimulus frequency (F3,143  =  29.37, p  <  0.001, and η2  =  0.35), bone (F5,143  =  4.61, p  =  0.001, and η2  =  0.01), and measurement site (F1,143  =  4.74, p  =  0.03, and η2  =  0.02) in the absence of statistically significant differences for the probe fixation method (F2,143  =  0.15, p  =  0.862, and η2  =  0.001). Standard deviations of the means were 6.9, 2.6, 1.9, and 0.6  nm  /  Pa for frequency, bone, site, and fixation, respectively. Ear transfer functions were found to be consistent with literature data.

CONCLUSIONS: The feasibility of applying HLFVP to measure the displacement of auditory ossicles has been confirmed. HLFVP offers the possibility of carrying out measurements at various angles; however, this needs to be standardized taking into account anatomical limitations and surgical convenience.