Analysis of B-Scan Ultrasonography Using Neural Networks to Predict Risk of Fibrosis in Patients With Metabolic Dysfunction-Associated Steatotic Liver Disease (MASLD).

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stansch Josefine, Trung Kien Vu, Blank Valentin, Kather Jakob Nikolas, Herzog Moritz, Seibel Tobias, Koop Paul-Henry, Haase Robert, Berg Thomas, Wiegand Johannes, Karlas Thomas

Аннотация

OBJECTIVE: The prevalence of metabolic dysfunction-associated steatotic liver disease (MASLD) continues to rise, underscoring the need for tools to stratify individual risk of disease progression. We evaluated whether logistic regression models augmented by deep learning-based predictions (DLPs) can improve the B-mode ultrasound-based identification of at-risk MASLD, defined as patients with increased fibrosis risk.

METHODS: We retrospectively analyzed 205 patients with a total of 636 ultrasound images. We developed a model that reproduces the LSM-based dichotomous fibrosis risk classification using clinical parameters and ultrasound image-derived deep learning pipelines. Patients were classified by same-day liver stiffness measurement (LSM) (<8 kPa: low fibrosis risk; ≥8 kPa: increased fibrosis risk). We assessed the incremental value of DLPs when added to the parameters sex, age, BMI, diabetes mellitus type 2 status and the fibrosis-4 score (FIB-4) based on accuracy, AUROC, and related statistics.

RESULTS: The logistic regression model combining the clinical parameters and the DLPs achieved acceptable performance with an AUROC of 0.73 and a test accuracy of 68%. The same model without DLPs showed an AUROC of 0.72 and a test accuracy of 61%. Including FIB-4 improved performance further (AUROC 0.92, accuracy 88%). Models based solely on image data demonstrated limited diagnostic performance.

CONCLUSION: B-mode ultrasound provides a weak fibrosis-related signal, yielding limited diagnostic performance. Meaningful discrimination required the incorporation of clinical parameters, with FIB-4 offering the greatest improvement among the parameters assessed. Deep learning predictions added only modest incremental value. Prospective validation is needed to clarify clinical utility.