Clinical implant dentistry and related research · 2018
Long-term stability of autologous bone graft of intraoral origin after lateral sinus floor elevation with simultaneous implant placement.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Maddalone Marcello, Mirabelli Luca, Venino Pier Matteo, Karanxha Lorena, Porcaro Gianluca, Del Fabbro Massimo
Аннотация
BACKGROUND: Lateral approach to maxillary sinus floor elevation (LSFE) with autologous bone grafts and simultaneous implant insertion is a widespread technique for prosthetic rehabilitation of the atrophic maxilla.
PURPOSE: To analyze implant survival and autologous bone graft resorption after LSFE, in patients with at least 5 years follow-up.
MATERIALS AND METHODS: Thirty-three patients (mean age 56 years, range 46-68 years) who had undergone LSFE with intraoral autologous bone graft from mandibular ramus and simultaneous implant insertion were included. A minimum of 5 years of follow-up was required. The total peri-implant bone height was measured at mesial and distal aspects of the implants immediately after surgery (T0) and after a period ranging from 5 to 11.5 years after surgery (mean 7.65 ± 1.80 years) (T1) on digital panoramic and periapical radiographs. Wilcoxon matched-pairs signed rank test was used to compare bone graft height at T0 and T1. The influence of patient-, surgery-, and implant-related factors on the outcomes was investigated.
RESULTS: Of the 58 implants placed, no one was lost. All prostheses were in function, and no biological or mechanical complications occurred. The residual ridge height at the involved sites averaged 6.48 ± 1.72 mm. The mean bone height at grafted regions was 12.05 ± 2.47 mm at T0 and 12.13 ± 2.39 mm at T1 (not statistically significant). Marginal bone level change at T1 averaged -1.22 ± 1.60 mm. None of the evaluated factors significantly affected the results.
CONCLUSION: Autologous bone grafts from intraoral donor sites display excellent volume stability over time that may contribute to optimal outcomes of the procedure.
PURPOSE: To analyze implant survival and autologous bone graft resorption after LSFE, in patients with at least 5 years follow-up.
MATERIALS AND METHODS: Thirty-three patients (mean age 56 years, range 46-68 years) who had undergone LSFE with intraoral autologous bone graft from mandibular ramus and simultaneous implant insertion were included. A minimum of 5 years of follow-up was required. The total peri-implant bone height was measured at mesial and distal aspects of the implants immediately after surgery (T0) and after a period ranging from 5 to 11.5 years after surgery (mean 7.65 ± 1.80 years) (T1) on digital panoramic and periapical radiographs. Wilcoxon matched-pairs signed rank test was used to compare bone graft height at T0 and T1. The influence of patient-, surgery-, and implant-related factors on the outcomes was investigated.
RESULTS: Of the 58 implants placed, no one was lost. All prostheses were in function, and no biological or mechanical complications occurred. The residual ridge height at the involved sites averaged 6.48 ± 1.72 mm. The mean bone height at grafted regions was 12.05 ± 2.47 mm at T0 and 12.13 ± 2.39 mm at T1 (not statistically significant). Marginal bone level change at T1 averaged -1.22 ± 1.60 mm. None of the evaluated factors significantly affected the results.
CONCLUSION: Autologous bone grafts from intraoral donor sites display excellent volume stability over time that may contribute to optimal outcomes of the procedure.