Compatibility of linezolid with commercial peritoneal dialysis solutions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Poeppl Wolfgang, Rainer-Harbach Elena, Kussmann Manuel, Pichler Petra, Zeitlinger Markus, Wiesholzer Martin, Burgmann Heinz, Reznicek Gottfried

Аннотация

PURPOSE: Results of a compatibility and stability study of linezolid admixed in commercial peritoneal dialysis (PD) solutions stored at various temperatures are reported.

METHODS: Test samples were prepared by adding linezolid i.v. injection (2 mg/mL) to infusion bags of 4 PD solutions (Extraneal, Nutrineal, Physioneal 40 Glucose 1.36%, and Physioneal 40 Glucose 2.27%, all from Baxter Healthcare Corporation). Assessments were conducted at various time points during storage of test samples at refrigeration temperature (6 °C) or room temperature (25 °C) for 14 days and at body temperature (37 °C) for 24 hours. Linezolid concentrations over time were determined by high-performance liquid chromatography, physical compatibility was determined by pH measurement and visual inspection, and antimicrobial activity was monitored by a disk diffusion method. The influence of solution warming by heating plate on drug stability was investigated.

RESULTS: Linezolid was stable in all tested solutions for 14 days at refrigeration and room temperatures and for 24 hours at body temperature. No linezolid adsorption to container material was detected. There were only minor variations in pH values, and visual inspection revealed no diluent abnormalities. With 1 exception, antimicrobial activity of >90% was retained in all PD solution samples for the duration of the study under all temperature conditions.

CONCLUSION: Linezolid injection 2 mg/mL remained stable and was compatible with the PD solutions studied for up to 2 weeks at refrigeration or room temperature and up to 24 hours at body temperature.