m+Medelevator.RU
← Поиск публикаций
Clinical implant dentistry and related research · 2024

Clinical efficacy of a two-piece abutment conforming to the concept of one abutment one time in the posterior region: A clinical pilot study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jiang Jimin, Yang Hang, Zhu Han, Bouhamed Ibrahim El Khalil, Shen Xiaoting, Lu Hongye, He Fuming

Аннотация

OBJECTIVES: To assess the impact of a two-piece abutment workflow on enhancing the stability of the alveolar bone and gingiva surrounding the dental implant, and to determine the level of patient satisfaction.

MATERIALS AND METHODS: A total of 48 patients with dentition defect in the posterior region were included and divided into two groups: the two-piece abutment workflow (TAW) and the sealing screw with submerged healing workflow (SHW). Marginal bone level (MBL), soft tissue indicators, oral hygiene indicators, and patient satisfaction were assessed and recorded partially at 0, 3, 6, and 12 months after surgery. The primary outcome was the change of MBL in different time periods. A generalized linear mixed model (GLMM) was used to take into account the correlated nature of the data, and adjust for potential confounding factors within inter-group differences.

RESULTS: The survival rate of implants and prosthesis reached 100% at 12-month follow-up, with an average decrease of 0.25 mm (SD 0.23 mm) of MBL in the TAW group and 0.48 mm (SD 0.45 mm) in the SHW group. The change of MBL in the TAW group (0.15 ± 0.31 mm) was significantly lower than the SHW group (0.41 ± 0.41 mm) through the analysis of GLMM within 6 months, while no significance was found in 12 months. Moreover, less gingival pain and oppression during prosthesis loading, and less time consumption overall duration were showed in the TAW group through Visual Analogue Scale (VAS, p < 0.05).

CONCLUSIONS: Within a 6-month period, the two-piece abutment workflow showed superior efficacy in preserving the integrity of the marginal bone level. Furthermore, it streamlined treatment procedures and mitigated discomfort, hence increasing patient satisfaction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты