m+Medelevator.RU
← Поиск публикаций
Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia · 2010

Mallampati test as a predictor of laryngoscopic view.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Adamus Milan, Fritscherova Sarka, Hrabalek Lumir, Gabrhelik Tomas, Zapletalova Jana, Janout Vladimir

Аннотация

AIM: To determine the accuracy of the modified Mallampati test for predicting difficult tracheal intubation.

DESIGN: A cross-sectional, clinical, observational, non-blinded study. A quality analysis of anesthetic care.

SETTING: Operating theatres and department of anesthesiology in a university hospital.

MATERIAL AND METHODS: Following the local ethics committee approval and patients' informed consent to anesthesia, all adult patients (> 18 yrs) presenting for any type of non-emergency surgical procedures under general anesthesia requiring endotracheal intubation were enrolled. Prior to anesthesia, Samsoon and Young's modification of the Mallampati test (modified Mallampati test) was performed. Following induction, the anesthesiologist described the laryngoscopic view using the Cormack-Lehane scale. Classes 3 or 4 of the modified Mallampati test were considered a predictor of difficult intubation. Grades 3 or 4 of the Cormack-Lehane classification of the laryngoscopic view were defined as impaired glottic exposure. The sensitivity, specificity, positive and negative predictive value, relative risk, likelihood ratio and accuracy of the modified Mallampati test were calculated on 2x2 contingency tables.

RESULTS: Of the total 1,518 patients enrolled, 48 had difficult intubation (3.2%). We failed to detect as many as 35.4% patients in whom glottis exposure during direct laryngoscopy was inadequate (sensitivity 0.646). Compared to the original article by Mallampati, we found lower specificity (0.824 vs. 0.995), lower positive predictive value (0.107 vs. 0.933), higher negative predictive value (0.986 vs. 0.928), lower likelihood ratio (3.68 vs. 91.0) and accuracy (0.819 vs. 0.929).

CONCLUSION: When used as a single examination, the modified Mallampati test is of limited value in predicting difficult intubation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты