MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc40787.2023.10339955

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023

Portable electrical impedance tomography (EIT) system stages non-alcoholic fatty liver disease for potential screening and monitoring at home.

Li James H W, Touboul Adrien, Zouari Fedi, Cheung Pak To, Wei Ellie, Wong Eddie C, Zhou Iris Y, Yuen Man-Fung, Seto Wai-Kay, Mak Lung-Yi, Chan Russell W

СтатьяПеревод пока не подготовлен

Аннотация

This study demonstrates the feasibility of predicting NAFLD using multi-spectral electrical impedance tomography (EIT), group source separation, constant reference EIT and anthropometric measures. Vibration-controlled Transient Elastography (VCTE) Controlled Attenuated Parameter (CAP; n = 121) and magnetic resonance imaging-proton density fat fraction (MRI-PDFF; n = 34) achieved a sensitivity of 70.9% and specificity of 73.8% with our CAP predicting model and sensitivity of 77.8% and specificity of 80.0% with our MRI-PDFF predicting model. In summary, a portable EIT can be a cost-effective and self-administrable alternative for widespread home-based and community-based diagnostic screening and treatment monitoring of NAFLD.Clinical Relevance- Portable multi-spectral EIT system has the sensitivity and specificity to potentially unlock biomedical imaging in telemedicine for home-based and community-based screening, staging and monitoring for NAFLD.

Для цитирования: Li James H W, Touboul Adrien, Zouari Fedi, Cheung Pak To, Wei Ellie, Wong Eddie C, Zhou Iris Y, Yuen Man-Fung, Seto Wai-Kay, Mak Lung-Yi, Chan Russell W. Portable electrical impedance tomography (EIT) system stages non-alcoholic fatty liver disease for potential screening and monitoring at home.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2023. DOI: 10.1109/embc40787.2023.10339955.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.