MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-024-05037-4

Медицинская библиотека · BMC oral health · 2024

Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques.

Awad Eman Mostafa, ElSheikh Mohamed Maamoun, El-Segai Azza Abd El Moneim

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Placing implants deep sub-gingivally may affect the accuracy of implant impression techniques and the fit of final restoration.

PURPOSE: The aim of this in-vitro study was to evaluate the effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques.

METHODS

Four parallel implant analogues (A, B, C, D) placed in each of two epoxy resin models representing edentulous mandible covered by flexible polyurethane material with two different thickness two mm and four mm. A total of sixty impressions performed, thirty impressions for each model divided into four groups (n = 15 per group) GI (C2mm) open tray impression with two mm implant depth, GII (C4mm) open tray impression with four mm implant depth, GIII (D2mm) digital impression with two mm implant depth, GIV (D 4 mm) digital impression with four mm implant depth. Impressions from open tray technique were poured to get stone casts while impressions from digital scanning technique were printed as three-dimensional printed casts. The six inter-implant distances between analogues were measured using Co-ordinate measuring machine, deviations compared to reference models were calculated. Data was collected, tabulated and statistically analyzed using One-way ANOVA test to detect significances between groups.

RESULTS

For conventional impressions there was significant difference between C2mm/C4mm (P < 0.001) regarding interimplant distance, while in digital impressions there was no significant difference between D2mm/D4mm AB(p = 0.110), BC(p = 0.066), CD(p = 0.710), AD(p = 0.084), AC(p = 0.067) and BD(p = 0.072). There was significant difference between conventional and digital impression techniques C2mm/D2mm, C4mm/D4mm (P < 0.001).

CONCLUSION

Within the limitations of this in-vitro study digital impressions provide more accurate outcomes with implants placed deeper subgingivally than conventional impressions.

TRIAL REGISTRATION: Retrospectively registered.

Для цитирования: Awad Eman Mostafa, ElSheikh Mohamed Maamoun, El-Segai Azza Abd El Moneim. Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques.. BMC oral health. 2024. DOI: 10.1186/s12903-024-05037-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.