Background and

Objectives

The aim of this study was to clinically evaluate the primary and secondary stability of dental implants with different macrodesigns using resonance frequency analysis and to determine whether implant design and length influence implant stability. Materials and methods: This study included 48 healthy patients receiving dental implants, and a pre-implant planning protocol was used, which involved detailed bone analysis, clinical examinations, and Cone beam computed tomography (CBCT) analysis. The implants were of various types and dimensions (Alpha-Bio Tec (Israel), DFI, SPI, and NEO), and the surgical procedures were performed using standard methods. Implant stability was measured using resonance frequency analysis (RFA) immediately after placement and after 3, 6, and 12 months. The total number of implants placed in all patients was 96.

Results

The average primary stability value for 10 mm SPI implants placed in the maxilla was 68.2 ± 1.7 Implant Stability Quotient (ISQ) units, while for 10 mm NEO implants, it was 74.0 ± 0.9. The average primary stability value for a 10 mm DFI implant placed in the mandible was 72.8 ± 1.2 ISQ, while for a 10 mm NEO implant placed in the mandible, it was 76.3 ± 0.8 ISQ. Based on the Friedman ANOVA test, the differences in the stability measurements for the 10 mm and 11.5 mm SPI implants and for the 10 mm and 11.5 mm NEO implants in the maxilla on day 0 and after 3, 6, and 12 months were significant at p < 0.05. Similarly, based on the Friedman ANOVA test, the differences in the stability measurements for the 10 mm and 11.5 mm DFI implants and for the 10 mm and 11.5 mm NEO implants in the mandible on day 0 and after 3, 6, and 12 months were significant at p < 0.05 (p = 0.00000).

Conclusions

Universal tapered implants of the NEO type stood out as the optimal choice, as they provided statistically significantly higher primary stability in both soft and hard bone types compared to other implants. The implant length did not significantly affect this stability.

Для цитирования: Popovski Julie, Mikic Mirko, Tasevski Dimitar, Dabic Sasa, Mladenovic Rasa. Comparing Implant Macrodesigns and Their Impact on Stability: A Year-Long Clinical Study.. Medicina (Kaunas, Lithuania). 2024. DOI: 10.3390/medicina60091546.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.