MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/1874471012666191015095550

Медицинская библиотека · Current radiopharmaceuticals · 2020

Malignant Cutaneous Melanoma: Updates in PET Imaging.

Laudicella Riccardo, Baratto Lucia, Minutoli Fabio, Baldari Sergio, Iagaru Andrei

СтатьяОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Cutaneous malignant melanoma is a neoplasm whose incidence and mortality are dramatically increasing. 18F-FDG PET/CT gained clinical acceptance over the past 2 decades in the evaluation of several glucose-avid neoplasms, including malignant melanoma, particularly for the assessment for distant metastases, recurrence and response to therapy.

OBJECTIVE

To describe the advancements of nuclear medicine for imaging melanoma with particular attention to 18F-FDG-PET and its current state-of-the-art technical innovations.

METHODS

A comprehensive search strategy was used based on SCOPUS and PubMed databases. From all studies published in English, we selected the articles that evaluated the technological insights of 18FFDG- PET in the assessment of melanoma.

RESULTS

State-of-the-art silicon photomultipliers based detectors ("digital") PET/CT scanners are nowadays more common, showing technical innovations that may have beneficial implications for patients with melanoma. Steady improvements in detectors design and architecture, as well as the implementation of both software and hardware technology (i.e., TOF, point spread function, etc.), resulted in significant improvements in PET image quality while reducing radiotracer dose and scanning time.

CONCLUSION

Recently introduced digital PET detector technology in PET/CT and PET/MRI yields higher intrinsic system sensitivity compared with the latest generation analog technology, enabling the detection of very small lesions with potential impact on disease outcome.

Для цитирования: Laudicella Riccardo, Baratto Lucia, Minutoli Fabio, Baldari Sergio, Iagaru Andrei. Malignant Cutaneous Melanoma: Updates in PET Imaging.. Current radiopharmaceuticals. 2020. DOI: 10.2174/1874471012666191015095550.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.