MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2002.21.8.909

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2002

Chorioangiomas of the placenta: sonographic and Doppler flow characteristics.

Zalel Yaron, Weisz Boaz, Gamzu Ronni, Schiff Eyal, Shalmon Bruria, Achiron Reuven

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate our experience with sonography and color Doppler blood flow in the diagnosis and management of chorioangiomas of the placenta.

METHODS

All cases with placental chorioangiomas diagnosed in our sonography unit between 1992 and 2001 were included in the study. Sonographic and color Doppler flow characteristics were evaluated in all cases. Our cases were compared with all cases of placental chorioangiomas diagnosed antenatally by sonography published in the English literature between 1978 and 2001.

RESULTS

Six cases of placental chorioangioma were identified antenatally, with a mean size of 6.5 cm (range, 4-13 cm). With the use of color Doppler flow, all cases of chorioangioma were shown to have either abundant blood flow or a large feeding vessel within the tumor. During follow-up, 2 cases had reduction of the intratumoral blood flow, and the outcomes were favorable. Three of our cases had delivery before 33 weeks' gestation (1 with intrauterine fetal death and 1 with termination of pregnancy). Review of the literature revealed 72 cases of antenatally diagnosed placental chorioangioma. Two thirds of the cases had dismal outcomes.

CONCLUSIONS

The sonographic diagnosis of chorioangiomas of the placenta is feasible and necessitates close surveillance of these pregnancies because of the dismal prognosis in more than half. The addition of color Doppler flow is important in the diagnosis and antenatal follow-up of these pregnancies.

Для цитирования: Zalel Yaron, Weisz Boaz, Gamzu Ronni, Schiff Eyal, Shalmon Bruria, Achiron Reuven. Chorioangiomas of the placenta: sonographic and Doppler flow characteristics.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2002. DOI: 10.7863/jum.2002.21.8.909.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.