MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0358772

Медицинская библиотека · PloS one · 2026

Serum Na-Cl value from routine blood tests reflects CO2 retention in amyotrophic lateral sclerosis.

Yamakawa Isamu, Tamura Ryota, Yabata Hiroyuki, Tsukamoto Takahito, Kobashi Shuhei, Tamaki Yoshitaka, Ogawa Nobuhiro, Kitamura Akihiro, Urushitani Makoto

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Respiratory failure is the leading cause of death in amyotrophic lateral sclerosis (ALS). Early detection of CO2 retention is crucial for assessing respiratory failure severity and guiding noninvasive positive pressure ventilation (NPPV) management. However, arterial blood gas analysis is invasive and uncomfortable for routine monitoring.

OBJECTIVE

We investigated whether the serum sodium-chloride difference (Na-Cl value), calculated from routine blood tests, could serve as a screening marker for CO2 retention in ALS patients.

METHODS

This retrospective study included 88 ALS patients with 116 paired samples of arterial blood gas and serum electrolyte data. We analyzed correlations between Na-Cl value and blood gas parameters (HCO3-, PCO2), performed receiver operating characteristic (ROC) analysis for detecting CO2 retention (PCO2 ≥ 45 mmHg), and examined relationships with respiratory function (%FVC).

RESULTS

Na-Cl value showed strong correlation with HCO3- (r = 0.78, p < 0.001) and PCO2 (r = 0.71, p < 0.001). Na-Cl ≥ 37 mEq/L demonstrated sensitivity of 85.11% and specificity of 69.57% for detecting PCO2 ≥ 45 mmHg, with negative predictive value of 87.27% (AUC = 0.842). Na-Cl ≥ 39 mEq/L achieved specificity of 92.75%. Patients with %FVC < 50% had significantly higher Na-Cl, PCO2, and HCO3- values.

CONCLUSIONS

Serum Na-Cl value serves as a simple, noninvasive screening marker for CO2 retention in ALS. Na-Cl ≥ 37 mEq/L warrants blood gas analysis, while Na-Cl ≥ 39 mEq/L provides specificity >90%. This marker can be calculated from routine blood tests without additional cost, making it suitable for frequent monitoring and reducing the risk of missing intervention timing.

Для цитирования: Yamakawa Isamu, Tamura Ryota, Yabata Hiroyuki, Tsukamoto Takahito, Kobashi Shuhei, Tamaki Yoshitaka, Ogawa Nobuhiro, Kitamura Akihiro, Urushitani Makoto. Serum Na-Cl value from routine blood tests reflects CO2 retention in amyotrophic lateral sclerosis.. PloS one. 2026. DOI: 10.1371/journal.pone.0358772.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.