Development of a modelling to correlate site and diameter of brain metastases with hippocampal sparing using volumetric modulated Arc therapy.

Chiesa Silvia, Balducci Mario, Azario Luigi, Gaudino Simona, Cellini Francesco, Mattiucci Gian Carlo, Colosimo Cesare, Valentini Vincenzo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To correlate site and diameter of brain metastases with hippocampal sparing in patients treated by RapidArc (RA) technique on whole brain with simultaneously integrated boost (SIB).

METHODS AND MATERIALS: An RA plan was calculated for brain metastases of 1-2-3 cm of diameter. The whole brain dose was 32.25 Gy (15 fractions), and SIB doses to brain metastases were 63 Gy (2 and 3 cm) or 70.8 Gy (1 cm). Plans were optimized and evaluated for conformity, target coverage, prescription isodose to target volume, homogeneity index, and hippocampal sparing.

RESULTS

Fifteen brain lesions and RA plan were generated. Hippocampal volume was 4.09 cm³, and hippocampal avoidance volume was 17.50 cm³. Related to site of metastases, the mean hippocampal dose was 9.68 Gy² for occipital lobe, 10.56 Gy² for frontal lobe, 10.56 Gy² for parietal lobe, 10.94 Gy² for deep brain structures, and 40.44 Gy² for temporal lobe. The mean hippocampal dose was 9.45 Gy², 10.15 Gy², and 11.70 Gy² for diameter's metastases of 1.2 and 3 cm, respectively, excluding results relative to temporal brain lesions.

CONCLUSIONS

Location more than size of metastases can adversely influence the hippocampus sparing. Further investigation is necessary to meet definitive considerations.

Для цитирования: Chiesa Silvia, Balducci Mario, Azario Luigi, Gaudino Simona, Cellini Francesco, Mattiucci Gian Carlo, Colosimo Cesare, Valentini Vincenzo. Development of a modelling to correlate site and diameter of brain metastases with hippocampal sparing using volumetric modulated Arc therapy.. BioMed research international. 2013. DOI: 10.1155/2013/568597.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.