MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15569845241286012

Медицинская библиотека · Innovations (Philadelphia, Pa.) · 2024

Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot.

Ashraf Syed Faaz, Seese Laura, Hasan Irsa S, Babu Ashok N, Balkhy Husam H, Kiaii Bob B, Guy T Sloane, Kaczorowski David J, Bonatti Johannes

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

We created and validated a low-cost simulation model for robotic internal mammary artery (IMA) takedown.

METHODS

The simulation model utilized a calf fetus thorax cavity stented open internally and secured to a table. The simulation model was validated at a 2-day robotic cardiac surgery workshop. Each participant harvested one IMA using the da Vinci Xi robot (Intuitive Surgical, Sunnyvale, CA, USA). We compared participant self-reported confidence at robotic IMA harvest before and after using the simulator.

RESULTS

Our novel thorax-securing strategy resulted in a stable structure and allowed access to both IMAs from the same 3 ports. The cost to set up the first simulation model was $176 and $133 for every subsequent model. Fifty participants used the simulation model: 42 cardiothoracic surgery attendings and 8 fellows or residents. The feedback form response rate was 78% (n = 39). On the Likert scale, participants rated realism of the calf model to simulate robotic IMA harvesting (0 = not realistic, 10 = highly realistic) with a median of 8 out of 10 (interquartile range [IQR] 7 to 9). Participant confidence (0 = not at all confident, 10 = very confident) in robotic IMA harvesting before and after using the simulator increased (P = 0.001) from a median of 5 (IQR 1 to 7) to 9 (IQR 7 to 10).

CONCLUSIONS

This robotic IMA harvest simulation model is affordable, realistic, and improved participant confidence in robotic IMA harvest. It may provide a valuable training tool for surgeons learning robotic coronary bypass surgery and allows for training frequency necessary to pass basic learning curves.

Для цитирования: Ashraf Syed Faaz, Seese Laura, Hasan Irsa S, Babu Ashok N, Balkhy Husam H, Kiaii Bob B, Guy T Sloane, Kaczorowski David J, Bonatti Johannes. Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot.. Innovations (Philadelphia, Pa.). 2024. DOI: 10.1177/15569845241286012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.