Williams Luke John Lloyd, Hogg Rachel, Roque Miguel Angel Reyes, Beale Sarah, Husain Mubassher, Jothidasan Anand, Zych Bart, Gerovasili Vicky, Kaul Pradeep, Tsui Steven, Smail Hassiba, Adhami Ahmed Al, Parmar Jasvir, Pettit Stephen, Periasamy Sri Aurovind, Mohite Prashant, Curry Philip, Messer Simon, Morcos Karim, Venkateswaran Rajamiyer, Mehta Vipin, Dronavalli Vamsidhar, Ramesh B C, Ranasinghe Aaron, Quinn David, Raj Binu, Sutcliffe Ruth, Suresh Dharmic, Johnston Chris, Pettigrew Gavin, Butler Andrew, Olland Anne, Hardman Gillian, Watson Christopher, Manas Derek, Currie Ian, Berman Marius
Аннотация
METHODS: Retrospective analysis of all 487 UK DCD lung donors between April 1, 2011 and December 31, 2023. Organ transplantation rate and 30-day, 90-day and 1-year survival rates were compared between DRP of DCD lungs, DRP of DCD lungs with A-NRP and donation after brainstem death (DBD) lungs. Primary graft dysfunction (PGD) rates were compared between DCD lungs with and without A-NRP.
RESULTS: Three hundred ninety-seven DCD donors resulted in a lung transplant (22 retrieved by DRP with A-NRP). There was no difference in lung transplantation rates between DRP and DRP with A-NRP. Of the 390 first adult-only lung transplants performed from DCD donors, there was no significant difference in 30-day, 90-day and 1-year survival between DRP of DCD lungs and DRP with A-NRP. There was a significant difference in survival between standard DCD donors and DBD donors at 30-days and 90-days, but not 1 year. There was no significant difference in grade 3 PGD rates at 72 hours post-implantation for DCD lungs with or without A-NRP.
CONCLUSION: In the UK experience, use of A-NRP is not detrimental to procurement of DCD lungs. We advocate the use of this technique until further studies can explore the safety and efficacy of thoraco-abdominal NRP for lungs in multi-organ retrieval.