MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhep.2014.12.007

Медицинская библиотека · Journal of hepatology · 2014

Real-time shear-wave elastography: applicability, reliability and accuracy for clinically significant portal hypertension.

Procopet Bogdan, Berzigotti Annalisa, Abraldes Juan G, Turon Fanny, Hernandez-Gea Virginia, García-Pagán Juan Carlos, Bosch Jaime

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND & AIMS: Real-time shear wave elastography (RT-SWE) might be useful to assess the severity of portal hypertension; reliability criteria for measurement are needed.

METHODS

We prospectively included 88 consecutive patients undergoing hepatic venous pressure gradient measurement (HVPG, reference standard) for portal hypertension. Liver stiffness (LS) was measured by RT-SWE and by transient elastography (TE). Spleen stiffness (SS) was measured by RT-SWE. Reliability criteria for RT-SWE were searched, and the accuracy of these techniques to identify HVPG ⩾10mmHg (clinically significant portal hypertension, CSPH) was tested and internally validated by bootstrapping analysis.

RESULTS

LS and SS by RT-SWE were feasible respectively in 87 (99%) and 58 (66%) patients. Both correlated with HVPG (LS: R=0.611, p<0.0001 and SS: R=0.514, p<0.0001). LS performed well for diagnosing CSPH (optimism corrected AUROC=0.858). Reliability of measurements was influenced by standard deviation (SD)/median ratio and depth. SD/median ⩽0.10 and depth of measurement <5.6cm were associated to 96.3% well classified for CSPH, while when one or none of the criteria were fulfilled the rates were 76.4% and 44.4%, respectively. Measurements fulfilling at least one criterion were considered acceptable; in these patients, RT-SWE performance to detect CSPH was excellent (AUROC=0.939; 95% CI: 0.865-1.000; p<0.0001; best cut-off: 15.4kPa). LS by RT-SWE and by TE were strongly correlated (R=0.795, p<0.0001) and performed similarly both in "per protocol" and in "intention-to-diagnose" analysis after applying reliability criteria.

CONCLUSIONS

LS by RT-SWE is an accurate method to diagnose CSPH if reliability criteria (SD/median ⩽0.10 and/or depth <5.6cm) are fulfilled.

Для цитирования: Procopet Bogdan, Berzigotti Annalisa, Abraldes Juan G, Turon Fanny, Hernandez-Gea Virginia, García-Pagán Juan Carlos, Bosch Jaime. Real-time shear-wave elastography: applicability, reliability and accuracy for clinically significant portal hypertension.. Journal of hepatology. 2014. DOI: 10.1016/j.jhep.2014.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.