MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2019.12.020

Медицинская библиотека · American journal of ophthalmology · 2019

Optical Coherence Tomography Structural Abnormality Detection in Glaucoma Using Topographically Correspondent Rim and Retinal Nerve Fiber Layer Criteria.

Yang Hongli, Luo Haomin, Hardin Christy, Wang Yaxing, Jeoung Jin Wook, Albert Cindy, Vianna Jayme R, Sharpe Glen P, Reynaud Juan, Demirel Shaban, Mansberger Steven L, Fortune Brad, Nicolela Marcelo, Gardiner Stuart K, Chauhan Balwantray C, Burgoyne Claude F

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: This study evaluated the ability of topographically correspondent (TC) minimum rim width (MRW) and peripapillary retinal nerve fiber layer thickness (pRNFLT) criteria to detect optical coherence tomography (OCT) structural abnormality in glaucoma (GL) and glaucoma suspect (GLS) eyes.

DESIGN

Retrospective cross-sectional study.

METHODS

A total of 196 GL eyes, 150 GLS eyes, and 303 heathy eyes underwent pRNFL and 24 radial optic nerve head OCT imaging and manual correction of the internal limiting membrane, Bruch's membrane opening (BMO), and outer pRNFL segmentations. MRW and pRNFLT were quantified in 6 Garway-Heath or 12 30-degree (clock-hour) sectors. OCT abnormality for each parameter was defined to be less than the 5th percentile of the healthy eye distribution. OCT abnormality for individual eyes was defined using global, sectoral, and combined parameter criteria that achieved ≥95% specificity in the healthy eyes. TC combination criteria required the sectoral location of MRW and pRNFLT abnormality to be topographically aligned and included comMR (a previously reported TC combination consisting of MRW and pRNFLT parameter: [MRW + pRNFLT × (average MRW healthy eyes/average pRNFLT healthy eyes) MRW].

RESULTS

TC sectoral criteria (1 Garway-Heath MRW + corresponding Garway-Heath RNFLT), (one 30-degree MRW + any 1 corresponding or adjacent 30-degree pRNFLT), 30-degree and Garway-Heath comMR-TI and global comMR were the best performing criteria, demonstrating (96%-99% specificity), 86%-91% sensitivity for GL, 80%-84% sensitivity for early GL (MD ≥ -4.0 dB) and 93%-96% sensitivity for moderate-to-advanced GL (MD < -4.0 dB).

CONCLUSIONS

Clinically intuitive TC MRW and pRNFLT combination criteria identified the sectoral location of OCT abnormality in GL eyes with high diagnostic precision.

Для цитирования: Yang Hongli, Luo Haomin, Hardin Christy, Wang Yaxing, Jeoung Jin Wook, Albert Cindy, Vianna Jayme R, Sharpe Glen P, Reynaud Juan, Demirel Shaban, Mansberger Steven L, Fortune Brad, Nicolela Marcelo, Gardiner Stuart K, Chauhan Balwantray C, Burgoyne Claude F. Optical Coherence Tomography Structural Abnormality Detection in Glaucoma Using Topographically Correspondent Rim and Retinal Nerve Fiber Layer Criteria.. American journal of ophthalmology. 2019. DOI: 10.1016/j.ajo.2019.12.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.