MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/23335432.2025.2556187

Медицинская библиотека · International biomechanics · 2025

Assessing single camera markerless motion capture with OpenSim inverse kinematics during upper limb activities of daily living.

Scott Bradley, McInnes Mhairi, Chadwick Edward K, Blana Dimitra

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This study evaluates the accuracy of single camera markerless motion capture (SCMoCap) using Microsoft's Azure Kinect, enhanced with inverse kinematics (IK) via OpenSim, for upper limb movement analysis. Twelve healthy adults performed ten upper-limb tasks, recorded simultaneously by OptiTrack (marker-based) and Azure Kinect (markerless) from frontal and sagittal views. Joint angles were calculated using two methods: (1) direct kinematics based on body coordinate frames and (2) inverse kinematics using OpenSim's IK tool with anatomical keypoints. Accuracy was evaluated using root mean square error (RMSE) and Bland-Altman analysis. Results indicated that the IK method slightly improved joint angle agreement with OptiTrack for simpler movements, with an average RMSE of 8° for shoulder elevation in the sagittal plane compared to 9° with the coordinate frame method. However, both methods had higher RMSEs for rotational measurements, with IK and coordinate frame methods at 21° for shoulder rotation in the sagittal plane. Forearm pronation-supination measurements were unreliable due to tracking limitations. These findings suggest that Kinect with IK improves accuracy for simpler movements but struggles with rotational joint mechanics. Future research should focus on enhancing markerless tracking algorithms to fully realise the benefits of IK.

Для цитирования: Scott Bradley, McInnes Mhairi, Chadwick Edward K, Blana Dimitra. Assessing single camera markerless motion capture with OpenSim inverse kinematics during upper limb activities of daily living.. International biomechanics. 2025. DOI: 10.1080/23335432.2025.2556187.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.