MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medicina60040588

Медицинская библиотека · Medicina (Kaunas, Lithuania) · 2024

Clinical Peri-Implant Parameters and Marginal Bone Loss for Early Mandibular Implant Overdentures: A Follow-Up of 60 Months.

AlHelal Abdulaziz A, Alzaid Abdulaziz A, Almujel Saad H, Alsaloum Mohammed, Alanazi Khalid K, Althubaitiy Ramzi O, Al-Aali Khulud A

СтатьяПеревод пока не подготовлен

Аннотация

Background and

Objectives

Despite the identified benefits of early implant loading, studies have questioned its advantages compared to delayed loading in edentulous patients. This study aimed to evaluate clinical peri-implant parameters and marginal bone loss around early placed and loaded mandibular implant overdentures with a 60-month follow-up. Materials and

Methods

In this prospective cohort study, 43 patients were enrolled to receive 86 early loading sub-crestal dental implants through prosthetic guides. Implant overdentures were supported by two isolated implant locator attachments between two mental foramens. Clinical peri-implant parameters, including plaque index (PI), bleeding index (BI), peri-implant pocket depth (PIPD), and marginal bone loss (MBL) were evaluated using standardized techniques at 1, 12, 24, 36, 48, and 60 months follow-up. At 60 months, complications associated with implant overdentures (IOD's) were noted. The mean comparison of peri-implant clinical parameters was performed through ANOVA test. A p-value of ≤0.05 was taken as significant.

Results

Out of the total 43 enrolled patients, 8 patients were lost during follow-up; as a result, 35 patients completed the 5 years follow-up. The mean values of PI, BI, and PIPD increased with no statistical difference (p > 0.05). For marginal bone loss, an increase in the mean values was noted at different time intervals with statistical differences (p < 0.001). The most common complications noted were loosening of the abutment, occlusal adjustment, retentive locator loosening and replacement, and relining of the denture.

Conclusions

Early placement of IODs failed to prevent bone loss over time and was associated with complications, predominantly consisting of abutment loosening, occlusal adjustments, broken retentive locator components, relining, and rebasing.

Для цитирования: AlHelal Abdulaziz A, Alzaid Abdulaziz A, Almujel Saad H, Alsaloum Mohammed, Alanazi Khalid K, Althubaitiy Ramzi O, Al-Aali Khulud A. Clinical Peri-Implant Parameters and Marginal Bone Loss for Early Mandibular Implant Overdentures: A Follow-Up of 60 Months.. Medicina (Kaunas, Lithuania). 2024. DOI: 10.3390/medicina60040588.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.