Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients.

Riegger Carolin, Koeninger Angela, Hartung Verena, Otterbach Friedrich, Kimmig Rainer, Forsting Michael, Bockisch Andreas, Antoch Gerald, Heusner Till A

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

FDG-PET/CT is increasingly being used for breast cancer staging. Its diagnostic accuracy in comparison to ultrasound as the standard non-invasive imaging modality for the evaluation of axillary lymph nodes has yet not been evaluated.

PURPOSE: To retrospectively compare the diagnostic value of full-dose, intravenously contrast-enhanced FDG-PET/CT and ultrasound for the detection of lymph node metastases in breast cancer patients.

MATERIAL AND

METHODS

Ninety patients (one patient with a bilateral carcinoma) (89 women, one man; mean age, 55.5 +/- 16.6 years) suffering from primary breast cancer underwent whole-body FDG-PET/CT and axillary ultrasound. The ipsilateral axillary fossa (n = 91) was evaluated for metastatic spread. The sensitivity, specificity, the positive predictive value (PPV), negative predictive value (NPV), and accuracy of both methods were calculated. The sensitivity and accuracy were statistically compared using the McNemar Test (P <0.05). Analyses were made on a patient basis. The number of patients with extra-axillary locoregional lymph node metastases exclusively detected by FDG-PET/CT was evaluated. For axillary lymph node metastases histopathology served as the reference standard.

RESULTS

The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases were 54%, 89%, 77%, 74%, and 75%, respectively. For ultrasound it was 38%, 78%, 54%, 65%, and 62%, respectively. FDG-PET/CT was significantly more accurate than ultrasound for the detection of axillary lymph node metastases (P = 0.019). There was no statistically significant difference between the sensitivity of both modalities (P = 0.0578). FDG-PET/CT detected extra-axillary locoregional lymph node metastases in seven patients (8%) that had not been detected by another imaging modality.

CONCLUSION

Though more accurate compared to ultrasound for evaluating the axillary lymph node status FDG-PET/CT is only as sensitive as ultrasound when it comes to the detection of axillary lymph node metastases. Due to the low sensitivity FDG-PET/CT cannot act as a substitute for Sentinel lymph node biopsy. FDG-PET/CT is able to detect previously unknown locoregional extra-axillary lymph node metastases.

Для цитирования: Riegger Carolin, Koeninger Angela, Hartung Verena, Otterbach Friedrich, Kimmig Rainer, Forsting Michael, Bockisch Andreas, Antoch Gerald, Heusner Till A. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients.. Acta radiologica (Stockholm, Sweden : 1987). 2012. DOI: 10.1258/ar.2012.110635.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.