Journal of clinical medicine · 2026
Validity of DEXA-Derived Thigh Muscle Quantification Against AI-Assisted CT: Inter-Limb Asymmetry Provides Superior Agreement over Absolute Values.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lee Do Kyung
Аннотация
Background/Objectives: This study evaluated the validity of DEXA-derived muscle quantification by assessing its agreement with AI-assisted CT measurements of muscle volume and intramuscular adipose tissue. It also examined whether inter-limb asymmetry improves DEXA-CT agreement beyond absolute DEXA values. The influence of lower-limb rotation on DEXA measurements was assessed, and the study aimed to clarify how DEXA should be obtained and interpreted to more accurately reflect true muscle status. Methods: Fifty-two patients who completed CT and DEXA within 14 days were included. CT was used to obtain pure muscle volume and intramuscular adipose tissue (IMAT) using a standardized AI segmentation protocol, and corresponding DEXA thigh segmentation provided lean mass and fat percentage. Position-specific correlation analysis, regression, and Bland-Altman agreement testing were performed for 104 limbs. The same analyses were applied to inter-limb differences to isolate within-person asymmetry and reduce between-person variance. Results: DEXA lean mass correlated with CT pure muscle volume (r = 0.776, p < 0.001), and inter-limb asymmetry further improved alignment with CT (r = 0.857, p < 0.001). However, DEXA fat mass asymmetry demonstrated no association with CT IMAT asymmetry (r = -0.004, p = 0.979). When results were stratified by the recorded rotational groups, the highest correlation was observed in the neutral position (r = 0.900, p < 0.001). Bland-Altman analyses showed wide limits of agreement for all absolute measurements, whereas inter-limb asymmetry demonstrated markedly narrower limits of agreement, indicating superior numerical consistency. Conclusions: Absolute DEXA estimates showed limited agreement with CT and varied with limb position. Inter-limb asymmetry improved lean mass assessment, whereas fat mass and percentage did not correspond to CT-based IMAT. DEXA may therefore be used as a complementary tool for evaluating regional muscle quantity, but not for assessing muscle quality.