m+Medelevator.RU
← Поиск публикаций
Tumori · 2011

Non-sentinel lymph node metastases in breast cancer patients with a positive sentinel lymph node: validation of five nomograms and development of a new predictive model.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lombardi Augusto, Maggi Stefano, Lo Russo Marzia, Scopinaro Francesco, Di Stefano Domenica, Pittau Maria Grazia, Tiberi Simone, Amanti Claudio

Аннотация

AIMS AND BACKGROUND: Discordance of intraoperative analysis with definitive histology of the sentinel lymph node in breast cancer leads to completion axillary lymph node dissection, which only in 35-50% shows additional nodal metastases. The aim of the study was to identify individual patient risk for non-sentinel lymph node metastases by validating several statistical methods present in the recent literature and by developing a new tool with the final goal of avoiding unnecessary completion axillary lymph node dissection.

METHODS: We retrospectively evaluated 593 primary breast cancer patients. Completion axillary lymph node dissection was performed in 139 with a positive sentinel lymph node. The predictive accuracy of five published nomograms (MSKCC, Tenon, Cambridge, Stanford and Gur) was measured by the area under the receiver operating characteristic curve. We then developed a new logistic regression model to compare performance. Our model was validated by the leave-one-out cross-validation method.

RESULTS: In 53 cases (38%), we found at least one metastatic non-sentinel lymph node. All the selected nomograms showed values greater than the 0.70 threshold, and our model reported a value of 0.77 (confidence interval = 0.69-0.86 and error rate = 0.28) and 0.72 (confidence interval = 0.63-0.81, error rate = 0.28) after the validation. With a 5% cutoff value, sensitivity was 98% and specificity 9%, for a cutoff of 10%, 96% and 2%, respectively.

CONCLUSIONS: All the nomograms were good discriminators, but the alternative developed model showed the best predictive accuracy in this Italian breast cancer sample. We still confirm that these models, very accurate in the institution of origin, require a new validation if used on other populations of patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты