m+Medelevator.RU
← Поиск публикаций
European journal of gastroenterology & hepatology · 2008

Prospective pilot evaluation of a new needle prototype for endoscopic ultrasonography-guided fine-needle aspiration: comparison of cytology and histology yield.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Papanikolaou Ioannis S, Adler Andreas, Wegener Katharina, Al-Abadi Hussain, Dürr Angelika, Koch Martin, Pohl Heiko, Abou-Rebyeh Hassan, Veltzke-Schlieker Wilfried, Wiedenmann Bertram, Rösch Thomas

Аннотация

OBJECTIVES: Endoscopic ultrasonography (EUS) with the adjunct of EUS-guided fine needle aspiration has become an important diagnostic modality in gastroenterologic oncology. EUS-guided fine needle aspiration mainly relies on cytology; data are scarce that compare cytology and histology. While testing a 22-gauge prototype needle, we prospectively compared the yield for both.

METHODS: Forty-two consecutive patients (27 male, 15 female; mean age 59.2 years, range: 17-90 years) were included. In each patient we aimed to make two needle passes, and if the material acquired appeared insufficient macroscopically (no in-room cytopathology was available), further passes were done. The material was sent for cytological and histological assessment.

RESULTS: A median number of two passes (range: 2-3) were uneventfully performed for pancreatic lesions (n=30), mediastinal and other lymph nodes/masses (n=8) and various other lesions (n=4) and yielded adequate material for cytology, histology or at least one of the two investigations in 62, 67 and 74% of patients, respectively. No false positive results were found (specificity 100%). Sensitivities were 58.6 and 65.5%, respectively, for cytology and histology alone; combined assessment increased sensitivity to 79.3%. When adjusted values were calculated, based only on those cases with adequate material, sensitivity was 89.5% for cytology and 85.7% for histology, and increased to 100% with combined assessment.

CONCLUSION: The new needle achieves sensitivities similar to those previously reported with no significant differences in sensitivity between cytology and histology. More effective tissue acquisition methods must be sought to improve overall results.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты