MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13048-018-0461-5

Медицинская библиотека · Journal of ovarian research · 2018

CT of ovarian cancer: 3D cinematic rendering for preoperative evaluation.

Jin Yi-Ren, Yang Xie-Lan, Li Qin-Qing, Yan Zhi-Ling, Yang Hong-Ying, Liao Chengde

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ovarian cancer is the second most common gynecologic malignancy. As the primary imaging modality, computed tomography (CT) can provide staging information for preoperative planning and determination of surgical resectability. As a new three-dimensional postprocessing tool for CT images, cinematic rendering (CR) has the potential to depict anatomic details accurately.

CASE PRESENTATION: (Case 1) A 44-year-old married woman was diagnosed with recurrent ovarian cancer. CT images indicated the recurrent nodules and masses in the pelvic cavity and the upper middle abdominal peritoneum. The CR image showed that the multiple metastatic lesions and lymph nodes could not be completely removed by reoperation. The patient agreed to receive continued chemotherapy. (Case 2) A 51-year-old woman was admitted to our hospital due to abdominal distension and defecation that had increased for 6 months, with aggravation over the past 3 days. CT examination found cystic and solid masses in the bilateral ovarian area. The CR image demonstrated that the ovarian mass violated the posterior wall of the bladder and the anterior rectal wall. The preoperational imaging evaluation ensured the safety of the operation.

CONCLUSION

CR could improve the visualization of ovarian cancer masses, metastatic lymph nodes, and peritoneal metastases. CR has a good clinical value and will be more helpful in the preoperational evaluation of ovarian cancer.

Для цитирования: Jin Yi-Ren, Yang Xie-Lan, Li Qin-Qing, Yan Zhi-Ling, Yang Hong-Ying, Liao Chengde. CT of ovarian cancer: 3D cinematic rendering for preoperative evaluation.. Journal of ovarian research. 2018. DOI: 10.1186/s13048-018-0461-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.