MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000453083

Медицинская библиотека · Cerebrovascular diseases extra · 2017

Measurement of Oxygen Desaturation Is Not Useful for the Detection of Aspiration in Dysphagic Stroke Patients.

Marian Thomas, Schröder Jens, Muhle Paul, Claus Inga, Oelenberg Stephan, Hamacher Christina, Warnecke Tobias, Suntrup-Krüger Sonja, Dziewas Rainer

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Dysphagia is one of the most dangerous symptoms of acute stroke. Various screening tools have been suggested for the early detection of this condition. In spite of conflicting results, measurement of oxygen saturation (SpO2) during clinical swallowing assessment is still recommended by different national guidelines as a screening tool with a decline in SpO2 ≥2% usually being regarded as a marker of aspiration. This paper assesses the sensitivity of SpO2 measurements for the evaluation of aspiration risk in acute stroke patients.

METHODS

Fifty acute stroke patients with moderate to severe dysphagia were included in this study. In all patients, fiberoptic endoscopic evaluation of swallowing (FEES) was performed according to a standardised protocol. Blinded to the results of FEES, SpO2 was monitored simultaneously. The degree of desaturation during/after swallows with aspiration was compared to the degree of desaturation during/after swallows without aspiration in a swallow-to-swallow analysis of each patient. To minimise potential confounders, every patient served as their control.

RESULTS

In each subject, a swallow with and a swallow without aspiration were analysed. Overall, aspiration seen in FEES was related to a minor decline in SpO2 (mean SpO2 without aspiration 95.54 ± 2.7% vs. mean SpO2 with aspiration 95.28 ± 2.7%). However, a significant desaturation ≥2% occurred only in 5 patients during/after aspiration. There was no correlation between aspiration/dysphagia severity or the amount of aspirated material and SpO2 levels.

CONCLUSIONS

According to this study, measurement of oxygen desaturation is not a suitable screening tool for the detection of aspiration in stroke patients.

Для цитирования: Marian Thomas, Schröder Jens, Muhle Paul, Claus Inga, Oelenberg Stephan, Hamacher Christina, Warnecke Tobias, Suntrup-Krüger Sonja, Dziewas Rainer. Measurement of Oxygen Desaturation Is Not Useful for the Detection of Aspiration in Dysphagic Stroke Patients.. Cerebrovascular diseases extra. 2017. DOI: 10.1159/000453083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.