MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/emermed-2011-200911

Медицинская библиотека · Emergency medicine journal : EMJ · 2012

How reliable and safe is full-body low-dose radiography (LODOX Statscan) in detecting foreign bodies ingested by adults?

Mantokoudis Georgios, Hegner Simone, Dubach Patrick, Bonel Harald Marcel, Senn Pascal, Caversaccio Marco Domenico, Exadaktylos Aristomenis K

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments.

DESIGN

This comparative cross-sectional study retrospectively assessed 28289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality.

RESULTS

A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography.

CONCLUSIONS

LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.

Для цитирования: Mantokoudis Georgios, Hegner Simone, Dubach Patrick, Bonel Harald Marcel, Senn Pascal, Caversaccio Marco Domenico, Exadaktylos Aristomenis K. How reliable and safe is full-body low-dose radiography (LODOX Statscan) in detecting foreign bodies ingested by adults?. Emergency medicine journal : EMJ. 2012. DOI: 10.1136/emermed-2011-200911.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.